logicalUplinkFailoverPolicy
CME-MIB ·
.1.3.6.1.4.1.2.3.51.2.4.9.3.7.9
Object
scalar
mandatory
r/w
Enumeration
Determines when to failover if both an IPv4 and IPv6 destination
have been configured.
If set to 'either' the system will failover if either of the
destination's link check fails. If set to 'both' then the IPv4
and IPv6 link checks must fail before a failover will happen.
NOTE: This MIB object is only applicable to systems with a standby MM.
Context
- MIB
- CME-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.4.9.3.7.9- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- uplinkCheckConfig
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | either |
2 | both |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| uplinkCheckEnabled mandatory Disable or enable network uplink checking for physical detection.
NOTE: This MIB object is only applicable to systems with a standby MM. | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.9.3.7.1 |
| uplinkCheckDelay mandatory Delay, in minutes (1-2880), between discovery of a failed network uplink and
the subsequent MM failover for physical detection.
NOTE: This MIB object is only applicable… | scalar | Integer32 | .1.3.6.1.4.1.2.3.51.2.4.9.3.7.2 |
| logicalUplinkDestination mandatory Destination IP for MM to check its logical link.
Specify a non-zero IP Address in order to enable logical uplink checking.
NOTE: This MIB object is only applicable to s… | scalar | RFC1155-SMIIpAddress | .1.3.6.1.4.1.2.3.51.2.4.9.3.7.3 |
| logicalUplinkCheckEnabled mandatory Disable or enable network uplink checking for logical detection.
logicalUplinkDestination must be set to a non-zero IP Address before enable
logical uplink checking.
NO… | scalar | Enumeration | .1.3.6.1.4.1.2.3.51.2.4.9.3.7.4 |
| logicalUplinkCheckDelay mandatory Delay, in minutes(1-2880), between discovery of a failed network uplink and
the subsequent MM failover for logical detection.
NOTE: This MIB object is only applicable t… | scalar | Integer32 | .1.3.6.1.4.1.2.3.51.2.4.9.3.7.5 |
| physicalUplinkCheckDelayInSecs mandatory Delay, in seconds(10-172800), between discovery of a failed network uplink and
the subsequent MM failover for physical detection.
NOTE: This MIB object is only applicab… | scalar | Integer32 | .1.3.6.1.4.1.2.3.51.2.4.9.3.7.6 |
| logicalUplinkCheckDelayInSecs mandatory Delay, in seconds(60-172800), between discovery of a failed network uplink and
the subsequent MM failover for logical detection.
NOTE: This MIB object is only applicabl… | scalar | Integer32 | .1.3.6.1.4.1.2.3.51.2.4.9.3.7.7 |
| logicalUplinkIPv6Destination mandatory Destination IP for MM to check its logical link using IPv6.
Specify a non-zero IP Address in order to enable logical uplink checking.
NOTE: This MIB object is only appl… | scalar | InetAddressIPv6 | .1.3.6.1.4.1.2.3.51.2.4.9.3.7.8 |