f3EsaProbeCOSConfigSoamPmExtFlrDeltaTNumLmPdus

CM-SA-MIB · .1.3.6.1.4.1.2544.1.12.8.1.20.1.2

Object

column r/w Unsigned32
This is the number of loss measurement PDUs. 
delta_t is this attribute multiplied by the 
loss measurement message period. 
For example, if SLM message period is 
100ms and this attribute is 10, 
then the delta_t is 1second.

Context

MIB
CM-SA-MIB
OID
.1.3.6.1.4.1.2544.1.12.8.1.20.1.2
Type
column
Access
readwrite
Status
current
Parent
f3EsaProbeCOSConfigSoamPmExtEntry
Table
f3EsaProbeCOSConfigSoamPmExtTable
Siblings
2

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 1-1000000

Related Objects

Sibling Objects