rlIpDhcpOpt82SuboptionConfigCircuitIdFormat
CISCOSB-BRIDGE-SECURITY ·
.1.3.6.1.4.1.9.6.1.101.112.5.2.1.3
Object
column
r/w
OctetString
Defines the CircuitId format. Default is an empty string. Empty string means that CircuitId is added in a default format. Non-empty string AND true value of rlIpDhcpOpt82SuboptionConfigCircuitIdSupported Scalar means that CircuitId is added in configured format
Context
- MIB
- CISCOSB-BRIDGE-SECURITY
- OID
.1.3.6.1.4.1.9.6.1.101.112.5.2.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- rlIpDhcpOpt82SuboptionConfigEntry
- Table
- rlIpDhcpOpt82SuboptionConfigTable
- Siblings
- 6
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-160
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rlIpDhcpOpt82SuboptionConfigIndex Entry index. Must be 1 | column | Integer32 | .1.3.6.1.4.1.9.6.1.101.112.5.2.1.1 |
| rlIpDhcpOpt82SuboptionConfigCircuitIdPayloadLength Returns CircuitId payload length. | column | Integer32 | .1.3.6.1.4.1.9.6.1.101.112.5.2.1.2 |
| rlIpDhcpOpt82SuboptionConfigRemoteIdPayloadLength Returns RemoteId payload length. | column | Integer32 | .1.3.6.1.4.1.9.6.1.101.112.5.2.1.4 |
| rlIpDhcpOpt82SuboptionConfigRemoteIdFormat Defines the RemoteId format. Default is an empty string. Empty string means that RemoteId is added in a default format.
Non-empty string AND true value of rlIpDhcpOpt82SuboptionCo… | column | OctetString | .1.3.6.1.4.1.9.6.1.101.112.5.2.1.5 |
| rlIpDhcpOpt82SuboptionConfigNumericTokenFormat Defines the format of numeric tokens included in the Circuit-id and Remote-ID sub-options string. | column | Enumeration | .1.3.6.1.4.1.9.6.1.101.112.5.2.1.6 |
| rlIpDhcpOpt82SuboptionConfigCircuitIdAuxFailFlag Defines whatever to fail the CircuitId Suboption configuration | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.6.1.101.112.5.2.1.7 |