c3gModemTemperAbateNotifThreshold

CISCO-WAN-3G-MIB · .1.3.6.1.4.1.9.9.661.1.1.1.18

Object

column r/w degrees Celsius C3gTemperature
The modem temperature abate threshold value.  If modem
temperature goes below the threshold and the value of
c3gModemTemperAbateNotifEnabled is 'true', the 
c3gModemTemperAbateNotif notification will be sent. The value
of c3gModemTemperAbateNotifThreshold should be less than or 
equal to the value of c3gModemTemperOnsetNotifThreshold.  
e.g. setting c3gModemTemperAbateNotifThreshold to 50 degree
Celsius and then setting c3gModemTemperOnsetNotifThreshold
to 40 degree Celsius is not allowed and will be rejected.

Context

MIB
CISCO-WAN-3G-MIB
OID
.1.3.6.1.4.1.9.9.661.1.1.1.18
Type
column
Access
readwrite
Status
current
Units
degrees Celsius
Parent
c3gWanCommonEntry

Syntax

degrees Celsius C3gTemperature

Values & Constraints

No enumerated values or constraints recorded.