vismChanUserMaxScrIngress

CISCO-VISM-CONN-MIB · .1.3.6.1.4.1.351.110.5.5.3.1.1.1.52

Object

column r/w cells-per-second Unsigned32
This object defines a user configured SCR (Sustained 
Cell Rate) for the PVC. SCR is used for vbr connection
types only. Although, based on the value of SCR, any kind
of traffic shaping is not done on the VISM card, this value
is useful for setting up the parameters for the end-to-end 
PVC. This value is expressed in units of cells per second.
This object defines the SCR value for the ingress direction 
of the PVC.
For a VOIP bearer PVC the max value is 80000.
For a VOIP control PVC the max value is 20000 increased as 
we will allow 248 endpoints.
For Aal2 the values remain the same (50000/60000).
If the user provides a value that is greater than vismConnPCR
then the SET request will be rejected.
For vbr connections the allowed range of values of SCR is from
15 - PCR.

Context

MIB
CISCO-VISM-CONN-MIB
OID
.1.3.6.1.4.1.351.110.5.5.3.1.1.1.52
Type
column
Access
readwrite
Status
current
Units
cells-per-second
Parent
vismChanCnfGrpEntry
Table
vismChanCnfGrpTable
Siblings
54

Syntax

cells-per-second Unsigned32

Values & Constraints

Object Constraints
range: 1-100000

Related Objects

Sibling Objects