cucsComputeRackUnitOperPwrTransSrc
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB ·
.1.3.6.1.4.1.9.9.719.1.9.35.1.63
Object
column
CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePowerTransitionSrc
Cisco UCS compute:RackUnit:operPwrTransSrc managed object property
Context
- MIB
- CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
- OID
.1.3.6.1.4.1.9.9.719.1.9.35.1.63- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cucsComputeRackUnitEntry
- Table
- cucsComputeRackUnitTable
- Siblings
- 71
Syntax
CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePowerTransitionSrc
- Source
- CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePowerTransitionSrc
- Base type
Enumeration
Values & Constraints
Type Values
0 | unknown |
1 | userUnknown |
2 | userFp |
3 | software |
4 | softwareMcserver |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cucsComputeRackUnitInstanceId Instance identifier of the managed object. | column | CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId | .1.3.6.1.4.1.9.9.719.1.9.35.1.1 |
| cucsComputeRackUnitCheckPoint Cisco UCS compute:RackUnit:checkPoint managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeCheckPoint | .1.3.6.1.4.1.9.9.719.1.9.35.1.10 |
| cucsComputeRackUnitConnPath Cisco UCS compute:RackUnit:connPath managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus | .1.3.6.1.4.1.9.9.719.1.9.35.1.11 |
| cucsComputeRackUnitConnStatus Cisco UCS compute:RackUnit:connStatus managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus | .1.3.6.1.4.1.9.9.719.1.9.35.1.12 |
| cucsComputeRackUnitDescr Cisco UCS compute:RackUnit:descr managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.13 |
| cucsComputeRackUnitDiscovery Cisco UCS compute:RackUnit:discovery managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeDiscovery | .1.3.6.1.4.1.9.9.719.1.9.35.1.14 |
| cucsComputeRackUnitFltAggr Cisco UCS compute:RackUnit:fltAggr managed object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.719.1.9.35.1.15 |
| cucsComputeRackUnitFsmDescr Cisco UCS compute:RackUnit:fsmDescr managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.16 |
| cucsComputeRackUnitFsmFlags Cisco UCS compute:RackUnit:fsmFlags managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.17 |
| cucsComputeRackUnitFsmPrev Cisco UCS compute:RackUnit:fsmPrev managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.18 |
| cucsComputeRackUnitFsmProgr Cisco UCS compute:RackUnit:fsmProgr managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.19 |
| cucsComputeRackUnitDn Cisco UCS compute:RackUnit:dn managed object property | column | CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn | .1.3.6.1.4.1.9.9.719.1.9.35.1.2 |
| cucsComputeRackUnitFsmRmtInvErrCode Cisco UCS compute:RackUnit:fsmRmtInvErrCode managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.20 |
| cucsComputeRackUnitFsmRmtInvErrDescr Cisco UCS compute:RackUnit:fsmRmtInvErrDescr managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.21 |
| cucsComputeRackUnitFsmRmtInvRslt Cisco UCS compute:RackUnit:fsmRmtInvRslt managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsConditionRemoteInvRslt | .1.3.6.1.4.1.9.9.719.1.9.35.1.22 |
| cucsComputeRackUnitFsmStageDescr Cisco UCS compute:RackUnit:fsmStageDescr managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.23 |
| cucsComputeRackUnitFsmStamp Cisco UCS compute:RackUnit:fsmStamp managed object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.719.1.9.35.1.24 |
| cucsComputeRackUnitFsmStatus Cisco UCS compute:RackUnit:fsmStatus managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.25 |
| cucsComputeRackUnitFsmTry Cisco UCS compute:RackUnit:fsmTry managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.26 |
| cucsComputeRackUnitId Cisco UCS compute:RackUnit:id managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeRackUnitId | .1.3.6.1.4.1.9.9.719.1.9.35.1.27 |
| cucsComputeRackUnitIntId Cisco UCS compute:RackUnit:intId managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.28 |
| cucsComputeRackUnitLc Cisco UCS compute:RackUnit:lc managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminTrigger | .1.3.6.1.4.1.9.9.719.1.9.35.1.29 |
| cucsComputeRackUnitRn Cisco UCS compute:RackUnit:rn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.3 |
| cucsComputeRackUnitLcTs Cisco UCS compute:RackUnit:lcTs managed object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.719.1.9.35.1.30 |
| cucsComputeRackUnitManagingInst Cisco UCS compute:RackUnit:managingInst managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsNetworkSwitchId | .1.3.6.1.4.1.9.9.719.1.9.35.1.31 |
| cucsComputeRackUnitModel Cisco UCS compute:RackUnit:model managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.32 |
| cucsComputeRackUnitName Cisco UCS compute:RackUnit:name managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.33 |
| cucsComputeRackUnitNumOfAdaptors Cisco UCS compute:RackUnit:numOfAdaptors managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.34 |
| cucsComputeRackUnitNumOfCores Cisco UCS compute:RackUnit:numOfCores managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.35 |
| cucsComputeRackUnitNumOfCpus Cisco UCS compute:RackUnit:numOfCpus managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.36 |
| cucsComputeRackUnitNumOfEthHostIfs Cisco UCS compute:RackUnit:numOfEthHostIfs managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.37 |
| cucsComputeRackUnitNumOfFcHostIfs Cisco UCS compute:RackUnit:numOfFcHostIfs managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.38 |
| cucsComputeRackUnitNumOfThreads Cisco UCS compute:RackUnit:numOfThreads managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.39 |
| cucsComputeRackUnitAdminPower Cisco UCS compute:RackUnit:adminPower managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminPowerState | .1.3.6.1.4.1.9.9.719.1.9.35.1.4 |
| cucsComputeRackUnitOperPower Cisco UCS compute:RackUnit:operPower managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState | .1.3.6.1.4.1.9.9.719.1.9.35.1.40 |
| cucsComputeRackUnitOperQualifier Cisco UCS compute:RackUnit:operQualifier managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeIssues | .1.3.6.1.4.1.9.9.719.1.9.35.1.41 |
| cucsComputeRackUnitOperState Cisco UCS compute:RackUnit:operState managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsLsOperState | .1.3.6.1.4.1.9.9.719.1.9.35.1.42 |
| cucsComputeRackUnitOperability Cisco UCS compute:RackUnit:operability managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability | .1.3.6.1.4.1.9.9.719.1.9.35.1.43 |
| cucsComputeRackUnitOriginalUuid Cisco UCS compute:RackUnit:originalUuid managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.44 |
| cucsComputeRackUnitPresence Cisco UCS compute:RackUnit:presence managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSlotStatus | .1.3.6.1.4.1.9.9.719.1.9.35.1.45 |
| cucsComputeRackUnitRevision Cisco UCS compute:RackUnit:revision managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.46 |
| cucsComputeRackUnitSerial Cisco UCS compute:RackUnit:serial managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.47 |
| cucsComputeRackUnitServerId Cisco UCS compute:RackUnit:serverId managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.48 |
| cucsComputeRackUnitTotalMemory Cisco UCS compute:RackUnit:totalMemory managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.49 |
| cucsComputeRackUnitAdminState Cisco UCS compute:RackUnit:adminState managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminState | .1.3.6.1.4.1.9.9.719.1.9.35.1.5 |
| cucsComputeRackUnitUuid Cisco UCS compute:RackUnit:uuid managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.50 |
| cucsComputeRackUnitVendor Cisco UCS compute:RackUnit:vendor managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.51 |
| cucsComputeRackUnitVersionHolder Cisco UCS compute:RackUnit:versionHolder managed object property | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.719.1.9.35.1.52 |
| cucsComputeRackUnitNumOfCoresEnabled Cisco UCS compute:RackUnit:numOfCoresEnabled managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.53 |
| cucsComputeRackUnitLowVoltageMemory Cisco UCS compute:RackUnit:lowVoltageMemory managed
object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePhysicalLowVoltageMemory | .1.3.6.1.4.1.9.9.719.1.9.35.1.54 |
| cucsComputeRackUnitMemorySpeed Cisco UCS compute:RackUnit:memorySpeed managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.55 |
| cucsComputeRackUnitUsrLbl Cisco UCS compute:RackUnit:usrLbl managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.56 |
| cucsComputeRackUnitMfgTime Cisco UCS compute:RackUnit:mfgTime managed object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.719.1.9.35.1.57 |
| cucsComputeRackUnitPartNumber Cisco UCS compute:RackUnit:partNumber managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.58 |
| cucsComputeRackUnitVid Cisco UCS compute:RackUnit:vid managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.59 |
| cucsComputeRackUnitAssignedToDn Cisco UCS compute:RackUnit:assignedToDn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.6 |
| cucsComputeRackUnitPolicyLevel Cisco UCS compute:RackUnit:policyLevel managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.60 |
| cucsComputeRackUnitPolicyOwner Cisco UCS compute:RackUnit:policyOwner managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner | .1.3.6.1.4.1.9.9.719.1.9.35.1.61 |
| cucsComputeRackUnitLocalId Cisco UCS compute:RackUnit:localId managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.62 |
| cucsComputeRackUnitDiscoveryStatus Cisco UCS compute:RackUnit:discoveryStatus managed
object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus | .1.3.6.1.4.1.9.9.719.1.9.35.1.64 |
| cucsComputeRackUnitNumOf40GAdaptorsWithOldFw Cisco UCS compute:RackUnit:numOf40GAdaptorsWithOldFw
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.66 |
| cucsComputeRackUnitNumOf40GAdaptorsWithUnknownFw Cisco UCS compute:RackUnit:numOf40GAdaptorsWithUnknownFw
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.67 |
| cucsComputeRackUnitFanSpeedConfigStatus Cisco UCS compute:RackUnit:fanSpeedConfigStatus
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.68 |
| cucsComputeRackUnitFanSpeedPolicyFault Cisco UCS compute:RackUnit:fanSpeedPolicyFault
managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentFanSpeedPolicyFault | .1.3.6.1.4.1.9.9.719.1.9.35.1.69 |
| cucsComputeRackUnitAssociation Cisco UCS compute:RackUnit:association managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAssociation | .1.3.6.1.4.1.9.9.719.1.9.35.1.7 |
| cucsComputeRackUnitAssetTag Cisco UCS compute:RackUnit:assetTag managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.70 |
| cucsComputeRackUnitKmipFault Cisco UCS compute:RackUnit:kmipFault managed object property | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.719.1.9.35.1.71 |
| cucsComputeRackUnitKmipFaultDescription Cisco UCS compute:RackUnit:kmipFaultDescription
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.719.1.9.35.1.72 |
| cucsComputeRackUnitPhysicalSecurity Cisco UCS compute:RackUnit:physicalSecurity managed
object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPhysicalSecurityState | .1.3.6.1.4.1.9.9.719.1.9.35.1.73 |
| cucsComputeRackUnitAvailability Cisco UCS compute:RackUnit:availability managed object property | column | CISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAvailability | .1.3.6.1.4.1.9.9.719.1.9.35.1.8 |
| cucsComputeRackUnitAvailableMemory Cisco UCS compute:RackUnit:availableMemory managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.719.1.9.35.1.9 |