llcPortAdminMaxRetransmits

CISCO-SNA-LLC-MIB · .1.3.6.1.4.1.9.10.8.1.1.1.1.8

Object

column r/w SNMPv2-SMIInteger32
This object denotes the default value for the
maximum number of times which LLCs on this port
shall retry a PDU following the expiration of
the acknowledgement timer, the P-bit timer or
the reject timer. When these retries are
exhausted, the link shall be declared inactive.
This count is referred to as 'N2' in the IEEE
802.2 specification [5].
              
This port default value may be overridden by a
non-zero SAP default value in the
llcSapAdminMaxretransmits object or by a
non-zero value in the llcCcAdminMaxRetransmits
object.

Context

MIB
CISCO-SNA-LLC-MIB
OID
.1.3.6.1.4.1.9.10.8.1.1.1.1.8
Type
column
Access
readwrite
Status
current
Parent
llcPortAdminEntry
Table
llcPortAdminTable
Siblings
15

Syntax

SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects