rttMonGrpScheduleAdminFrequency
CISCO-RTTMON-MIB ·
.1.3.6.1.4.1.9.9.42.1.2.14.1.4
Object
column
r/w
seconds Integer32
Specifies the duration between initiating each RTT
operation for all the probes specified in the group.
The value of this object is only effective when both
rttMonGrpScheduleAdminFreqMax and rttMonGrpScheduleAdminFreqMin
have zero values.
Context
- MIB
- CISCO-RTTMON-MIB
- OID
.1.3.6.1.4.1.9.9.42.1.2.14.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- rttMonGrpScheduleAdminEntry
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 0-604800