cntpSysSrvStatus
CISCO-NTP-MIB ·
.1.3.6.1.4.1.9.9.168.1.1.11
Object
scalar
Enumeration
Current state of the NTP server with values coded as follows: 1: server status is unknown 2: server is not running 3: server is not synchronized to any time source 4: server is synchronized to its own local clock 5: server is synchronized to a local hardware refclock (e.g. GPS) 6: server is synchronized to a remote NTP server
Context
- MIB
- CISCO-NTP-MIB
- OID
.1.3.6.1.4.1.9.9.168.1.1.11- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- cntpSystem
- Siblings
- 10
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | unknown |
2 | notRunning |
3 | notSynchronized |
4 | syncToLocal |
5 | syncToRefclock |
6 | syncToRemoteServer |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cntpSysLeap Two-bit code warning of an impending leap second to
be inserted in the NTP timescale. This object can be
set only when the cntpSysStratum has a value of 1. | scalar | NTPLeapIndicator | .1.3.6.1.4.1.9.9.168.1.1.1 |
| cntpSysClock The current local time. Local time is derived from
the hardware clock of the particular machine and
increments at intervals depending on the design used. | scalar | NTPTimeStamp | .1.3.6.1.4.1.9.9.168.1.1.10 |
| cntpSysStratum The stratum of the local clock. If the value is set
to 1, i.e., this is a primary reference, then the
Primary-Clock procedure described in Section 3.4.6,
in RFC-1305 is invoked. | scalar | NTPStratum | .1.3.6.1.4.1.9.9.168.1.1.2 |
| cntpSysPrecision Signed integer indicating the precision
of the system clock, in seconds to the nearest
power of two. The value must be rounded to the
next larger power of two; for instance, a 50… | scalar | Integer32 | .1.3.6.1.4.1.9.9.168.1.1.3 |
| cntpSysRootDelay A signed fixed-point number indicating the total
round-trip delay in seconds, to the primary reference
source at the root of the synchronization subnet. | scalar | seconds NTPSignedTimeValue | .1.3.6.1.4.1.9.9.168.1.1.4 |
| cntpSysRootDispersion The maximum error in seconds, relative to the
primary reference source at the root of the
synchronization subnet. Only positive values greater
than zero are possible. | scalar | seconds NTPUnsignedTimeValue | .1.3.6.1.4.1.9.9.168.1.1.5 |
| cntpSysRefId The reference identifier of the local clock. | scalar | NTPRefId | .1.3.6.1.4.1.9.9.168.1.1.6 |
| cntpSysRefTime The local time when the local clock was last
updated. If the local clock has never been
synchronized, the value is zero. | scalar | NTPTimeStamp | .1.3.6.1.4.1.9.9.168.1.1.7 |
| cntpSysPoll The interval at which the NTP server polls other NTP
servers to synchronize its clock. | scalar | NTPPollInterval | .1.3.6.1.4.1.9.9.168.1.1.8 |
| cntpSysPeer The current synchronization source. This will
contain the unique association identifier
cntpPeersAssocId of the corresponding peer entry in
the cntpPeersVarTable of the peer acti… | scalar | NTPAssocIdentifier | .1.3.6.1.4.1.9.9.168.1.1.9 |