cnsInpSrcNetsyncIndex
CISCO-NETSYNC-MIB ·
.1.3.6.1.4.1.9.9.761.1.1.3.1.1
Object
column
Unsigned32
An index that uniquely represents an entry in this table. This index is assigned arbitrarily by the clock selection process and may not be persistent across reboots.
Context
- MIB
- CISCO-NETSYNC-MIB
- OID
.1.3.6.1.4.1.9.9.761.1.1.3.1.1- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- cnsInputSourceEntry
- Table
- cnsInputSourceTable
- Siblings
- 18
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cnsInpSrcQualityLevelRx This object indicates the last clock quality
level received on the input clock source. | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.10 |
| cnsInpSrcQualityLevel This object indicates the current clock quality
level of the input clock source. This is the
effective quality which is derived from three values:
1) most recent c… | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.11 |
| cnsInpSrcHoldoffTime This object indicates the hold-off time value of
an input clock source.
The hold-off time prevents short activation of signal failure
is passed to the selection pro… | column | milliseconds Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.3.1.12 |
| cnsInpSrcWtrTime This object indicates the wait-to-restore time value
of an input clock source.
The wait-to-restore time ensures that a previous failed
synchronization source is onl… | column | Seconds Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.3.1.13 |
| cnsInpSrcLockout This object indicates whether or not the lockout
command has been applied to a clock source.
The 'true' value means the clock source is not
considered by the select… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.14 |
| cnsInpSrcSignalFailure This object indicates whether or not a
signal failure event is currently being
reported on the input clock source. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.15 |
| cnsInpSrcAlarm This object indicates whether or not an
alarm event is currently being reported
on the input clock source. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.16 |
| cnsInpSrcAlarmInfo This object indicates the alarm reasons of
an input clock source if an alarm event
is being reported on it. | column | CiscoNetsyncAlarmInfo | .1.3.6.1.4.1.9.9.761.1.1.3.1.17 |
| cnsInpSrcFSW This object indicates the forced switching flag.
Forced switching, as described in G.781, is used to
override the currently selected synchronization source.
The 'tr… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.18 |
| cnsInpSrcMSW This object indicates the manual switching flag.
The 'true' value indicates the currently selected clock source
is a result of the manual switching. The switch allo… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.19 |
| cnsInpSrcName This object indicates the name of an input
clock source configured for the T0 clock
selection. | column | OctetString | .1.3.6.1.4.1.9.9.761.1.1.3.1.2 |
| cnsInpSrcIntfType This object indicates the type of an input
clock source configured for the T0 clock
selection. | column | CiscoNetsyncIfType | .1.3.6.1.4.1.9.9.761.1.1.3.1.3 |
| cnsInpSrcPriority This object indicates the priority of an input
clock source configured for the T0 clock
selection.
A smaller value represents a higher priority. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.3.1.4 |
| cnsInpSrcESMCCap This object indicates the ESMC capability
of an input clock source configured for the
T0 clock selection. This is applicable only to Synchronous
Ethernet input clock source ident… | column | CiscoNetsyncESMCCap | .1.3.6.1.4.1.9.9.761.1.1.3.1.5 |
| cnsInpSrcSSMCap This object indicates the SSM capability
of an input clock source configured for the
T0 clock selection. This is applicable only to
any synchronous interface clock source except
S… | column | CiscoNetsyncSSMCap | .1.3.6.1.4.1.9.9.761.1.1.3.1.6 |
| cnsInpSrcQualityLevelTxCfg This object indicates the configured transmit
clock quality level of an input clock source. | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.7 |
| cnsInpSrcQualityLevelRxCfg This object indicates the configured receive
clock quality level of an input clock source. | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.8 |
| cnsInpSrcQualityLevelTx This object indicates the most recent clock
quality level transmitted on the input clock
source. | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.9 |