cnsInpSrcHoldoffTime
CISCO-NETSYNC-MIB ·
.1.3.6.1.4.1.9.9.761.1.1.3.1.12
Object
column
milliseconds Unsigned32
This object indicates the hold-off time value of
an input clock source.
The hold-off time prevents short activation of signal failure
is passed to the selection process. When a signal failure
event is reported on a clock source, it waits the duration of
the hold-off time before declaring signal failure on the clock
source.
Context
- MIB
- CISCO-NETSYNC-MIB
- OID
.1.3.6.1.4.1.9.9.761.1.1.3.1.12- Type
- column
- Access
- readonly
- Status
- current
- Units
- milliseconds
- Parent
- cnsInputSourceEntry
- Table
- cnsInputSourceTable
- Siblings
- 18
Syntax
milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 0-4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cnsInpSrcNetsyncIndex An index that uniquely represents an entry in
this table. This index is assigned arbitrarily
by the clock selection process and may not be persistent
across reboots. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.3.1.1 |
| cnsInpSrcQualityLevelRx This object indicates the last clock quality
level received on the input clock source. | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.10 |
| cnsInpSrcQualityLevel This object indicates the current clock quality
level of the input clock source. This is the
effective quality which is derived from three values:
1) most recent c… | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.11 |
| cnsInpSrcWtrTime This object indicates the wait-to-restore time value
of an input clock source.
The wait-to-restore time ensures that a previous failed
synchronization source is onl… | column | Seconds Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.3.1.13 |
| cnsInpSrcLockout This object indicates whether or not the lockout
command has been applied to a clock source.
The 'true' value means the clock source is not
considered by the select… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.14 |
| cnsInpSrcSignalFailure This object indicates whether or not a
signal failure event is currently being
reported on the input clock source. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.15 |
| cnsInpSrcAlarm This object indicates whether or not an
alarm event is currently being reported
on the input clock source. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.16 |
| cnsInpSrcAlarmInfo This object indicates the alarm reasons of
an input clock source if an alarm event
is being reported on it. | column | CiscoNetsyncAlarmInfo | .1.3.6.1.4.1.9.9.761.1.1.3.1.17 |
| cnsInpSrcFSW This object indicates the forced switching flag.
Forced switching, as described in G.781, is used to
override the currently selected synchronization source.
The 'tr… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.18 |
| cnsInpSrcMSW This object indicates the manual switching flag.
The 'true' value indicates the currently selected clock source
is a result of the manual switching. The switch allo… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.3.1.19 |
| cnsInpSrcName This object indicates the name of an input
clock source configured for the T0 clock
selection. | column | OctetString | .1.3.6.1.4.1.9.9.761.1.1.3.1.2 |
| cnsInpSrcIntfType This object indicates the type of an input
clock source configured for the T0 clock
selection. | column | CiscoNetsyncIfType | .1.3.6.1.4.1.9.9.761.1.1.3.1.3 |
| cnsInpSrcPriority This object indicates the priority of an input
clock source configured for the T0 clock
selection.
A smaller value represents a higher priority. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.3.1.4 |
| cnsInpSrcESMCCap This object indicates the ESMC capability
of an input clock source configured for the
T0 clock selection. This is applicable only to Synchronous
Ethernet input clock source ident… | column | CiscoNetsyncESMCCap | .1.3.6.1.4.1.9.9.761.1.1.3.1.5 |
| cnsInpSrcSSMCap This object indicates the SSM capability
of an input clock source configured for the
T0 clock selection. This is applicable only to
any synchronous interface clock source except
S… | column | CiscoNetsyncSSMCap | .1.3.6.1.4.1.9.9.761.1.1.3.1.6 |
| cnsInpSrcQualityLevelTxCfg This object indicates the configured transmit
clock quality level of an input clock source. | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.7 |
| cnsInpSrcQualityLevelRxCfg This object indicates the configured receive
clock quality level of an input clock source. | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.8 |
| cnsInpSrcQualityLevelTx This object indicates the most recent clock
quality level transmitted on the input clock
source. | column | CiscoNetsyncQualityLevel | .1.3.6.1.4.1.9.9.761.1.1.3.1.9 |