cnsClkSelGlobalEntry
CISCO-NETSYNC-MIB ·
.1.3.6.1.4.1.9.9.761.1.1.1.1
Object
row
An entry is added to cnsClkSelGlobalTable when G.781 clock selection is enabled in the device configuration. The entry is removed when G.781 clock selection is removed from the configuration.
Context
- MIB
- CISCO-NETSYNC-MIB
- OID
.1.3.6.1.4.1.9.9.761.1.1.1.1- Type
- row
- Status
- current
- Parent
- cnsClkSelGlobalTable
- Table
- cnsClkSelGlobalTable
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cnsClkSelGloProcIndex An index that uniquely represents a clock selection process.
This index is assigned arbitrarily by the system
and may not be persistent across reboots. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.1.1.1 |
| cnsClkSelGlobWtrTime This object indicates the global
wait-to-restore time in the G.781
clock selection process. | column | seconds Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.1.1.10 |
| cnsClkSelGlobNofSources This object indicates the number of
synchronization sources currently
configured for the G.781
clock selection process. | column | clock sources Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.1.1.11 |
| cnsClkSelGlobLastHoldoverSeconds This object indicates the duration of
the last holdover period in seconds.
If the holdover duration is less than a second,
the object will carry the value zero. | column | seconds SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.761.1.1.1.1.12 |
| cnsClkSelGlobCurrHoldoverSeconds This object indicates the duration of
the current holdover period.
If a system clock is in holdover mode,
the object carries the current holdover
duration in seconds. If the syste… | column | seconds SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.761.1.1.1.1.13 |
| cnsClkSelGlobProcessMode This object indicates the QL mode of
the network synchronization clock selection
process as described in ITU-T standard G.781
section 5.12. | column | CiscoNetsyncQLMode | .1.3.6.1.4.1.9.9.761.1.1.1.1.2 |
| cnsClkSelGlobClockMode This object indicates the operating mode
of the system clock. | column | CiscoNetsyncClockMode | .1.3.6.1.4.1.9.9.761.1.1.1.1.3 |
| cnsClkSelGlobNetsyncEnable This object indicates whether the G.781
clock selection is enabled or not.
'true' - G.781 clock selection is enabled
'false' - G.781 clock selection is disabled | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.1.1.4 |
| cnsClkSelGlobRevertiveMode This object indicates the revertive mode
setting in the G.781 clock selection process.
The switching of clock sources can be made revertive or
non-revertive. In non… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.1.1.5 |
| cnsClkSelGlobESMCMode This object indicates if global ESMC is enabled.
With ESMC enabled globally, the system is capable
of handling ESMC messages. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.761.1.1.1.1.6 |
| cnsClkSelGlobEECOption This object indicates the network synchronization
EEC (Ethernet Equipment Clock) option. | column | CiscoNetsyncEECOption | .1.3.6.1.4.1.9.9.761.1.1.1.1.7 |
| cnsClkSelGlobNetworkOption This object indicates the synchronization
network option. | column | CiscoNetsyncNetworkOption | .1.3.6.1.4.1.9.9.761.1.1.1.1.8 |
| cnsClkSelGlobHoldoffTime This object indicates the global
holdoff time in the G.781 clock
selection process. | column | milliseconds Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.1.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| cnsClkSelGloProcIndex An index that uniquely represents a clock selection process.
This index is assigned arbitrarily by the system
and may not be persistent across reboots. | column | Unsigned32 | .1.3.6.1.4.1.9.9.761.1.1.1.1.1 |