ciscoGsccpSegReassUnsup
CISCO-ITP-GSCCP-MIB ·
.1.3.6.1.4.1.9.9.335.0.4
Object
notification
This notification is generated initially when a SCCP message is dropped due to a segmentation or reassembly unsupported or failure errors in last interval specified by the cgsccpGttErrorPeriod and the cgsccpInstErrorIndicator will be set to true. The notification will also be generated after the number of recovery intervals as specified by the cgsccpGttErrorRecoveryCount object has passed without any segmentation or reassembly unsupported errors.
Context
- MIB
- CISCO-ITP-GSCCP-MIB
- OID
.1.3.6.1.4.1.9.9.335.0.4- Type
- notification
- Status
- current
- Parent
- ciscoGsccpMIBNotifs
- Siblings
- 6
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ciscoGsccpGttMapStateChange The notification generated when a mated
application subsystem changes to a new state.
The value of cgsccpGttMapSsStatus indicates
the new state for the subsystem. | notification | - | .1.3.6.1.4.1.9.9.335.0.1 |
| ciscoGsccpGttLoadTable This notification is generated whenever a load
operation is started or completes. | notification | - | .1.3.6.1.4.1.9.9.335.0.2 |
| ciscoGsccpGttErrors This notification is generated whenever any global
title error is encountered in last interval specified
by the cgsccpGttErrorPeriod and the
cgsccpInstErrorIndicator will be set t… | notification | - | .1.3.6.1.4.1.9.9.335.0.3 |
| ciscoGsccpSOGReceived This notification is generated initially when a Subsystem
Out-of-Service Grant is sent in response to a Subsystem
Out-of-Service Request message. The affected PC and affected
SSN … | notification | - | .1.3.6.1.4.1.9.9.335.0.5 |
| ciscoGsccpRmtCongestion This notification is generated initially when congestion is
experienced in the remote SCCP component for the first time in
last interval specified by the cgsccpGttErrorPeriod. Th… | notification | - | .1.3.6.1.4.1.9.9.335.0.6 |
| ciscoGsccpLocalSsStateChange The notification generated when a local application subsystem
changes to a new state. The subsystem number and the latest
subsystem state will be provided in this notification. | notification | - | .1.3.6.1.4.1.9.9.335.0.7 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| CISCO-ITP-GSP-MIBcgspEventSequenceNumber Each event or notification is required to provide a
sequence number to be used by the NMS to determine when
messages from a particular device are missing. This value
will include… | scalar | events SNMPv2-SMICounter32 | .1.3.6.1.4.1.9.9.336.1.1.6 |
| CISCO-ITP-GSP-MIBcgspCLLICode Common-Language Location Identification Codes
(CLLI Codes). This object identifies the
physical location of this device and can provide
additional informaton on the device type. | scalar | CISCO-ITP-TC-MIBCItpTcCLLI | .1.3.6.1.4.1.9.9.336.1.1.1 |
| cgsccpInstErrorIndicator This object indicates whether global title
translation errors have occurred in last interval
specified by the cgsccpGttErrorPeriod object. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.335.1.2.1.1.43 |
| cgsccpGttErrorsReassUnsupported This counter is incremented every time when the
incoming SCCP message needs to be dropped due
to the unsupported reassembly feature. This
counter is derived from cgsccpInstReassUn… | column | packets SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.335.1.12.1.1.14 |
| cgsccpGttErrorsReassFailure This counter is incremented every time when the
incoming SCCP message needs to be dropped due
to the reassembly failure. This counter is derived
from cgsccpInstReassFail object. | column | packets SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.335.1.12.1.1.15 |
| cgsccpGttErrorsSegUnsupported This counter is incremented every time when either
SCCP message from a remote node or local SCCP stack
needs to be dropped due to the unsupported
segmentation feature. This counte… | column | packets SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.335.1.12.1.1.16 |
| cgsccpGttErrorsSegFailure This counter is incremented every time when either
SCCP message from a remote node or local SCCP stack
needs to be dropped due to the segmentation failure.
This counter is derive… | column | packets SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.335.1.12.1.1.17 |