cifthThresholdDirection
CISCO-IF-THRESHOLD-MIB ·
.1.3.6.1.4.1.9.9.218.1.1.5.1.6
Object
column
r/w
Enumeration
This object indicates which direction of movement causes the
threshold to fire.
The value 'rising' indicates that the threshold is fired when
the current sampled value is numerically greater than or equal
to the value of cifthThresholdFiredValue, and the threshold was
considered to be cleared at the last sampling interval. If the
value of the corresponding cifthTemplateNotifyHoldDownType
object is 'fireAndClearThresholds', the threshold is cleared
when the current sampled value is less than the value of
cifthThresholdClearedValue, and the threshold was considered to
be fired at the last sampling interval. If the value of the
corresponding cifthTemplateNotifyHoldDownType object is other
than 'fireAndClearThresholds', the threshold is cleared when
the current sampled value is less than the value of
cifthThresholdFiredValue, and the threshold was considered to
be fired at the last sampling interval.
The value 'falling' indicates that the threshold is fired when
the current sampled value is numerically less than or equal to
the value of cifthThresholdFiredValue, and the threshold was
considered to be cleared at the last sampling interval. If the
value of the corresponding cifthTemplateNotifyHoldDownType
object is 'fireAndClearThresholds', the threshold is cleared
when the current sampled value is greater than the value of
cifthThresholdClearedValue, and the threshold was considered to
be fired at the last sampling interval. If the value of the
corresponding cifthTemplateNotifyHoldDownType object is other
than 'fireAndClearThresholds', the threshold is cleared when
the current sampled value is greater than the value of
cifthThresholdFiredValue, and the threshold was considered to
be fired at the last sampling interval.
Context
- MIB
- CISCO-IF-THRESHOLD-MIB
- OID
.1.3.6.1.4.1.9.9.218.1.1.5.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cifthThresholdEntry
- Table
- cifthThresholdTable
- Siblings
- 10
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | rising |
2 | falling |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cifthThresholdIndex An arbitrary integer that uniquely identifies a threshold in
a threshold template. The value for each threshold must remain
constant when the agent's network management system is… | column | CifthThresholdIndex | .1.3.6.1.4.1.9.9.218.1.1.5.1.1 |
| cifthThresholdApsSwitchover This object indicates whether automatic protection switching
(APS) switchover should be triggered, if applicable, when the
threshold is fired. The value of this object takes effe… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.218.1.1.5.1.10 |
| cifthThresholdRowStatus This object is used to create and delete thresholds in
templates.
A new entry can only be created when there is an active entry
in the cifthTemplateTable with the s… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.9.9.218.1.1.5.1.11 |
| cifthThresholdDescr A description of the threshold's function and use. The
description must not include carriage returns. | column | OctetString | .1.3.6.1.4.1.9.9.218.1.1.5.1.2 |
| cifthThresholdObject The object to be compared against the threshold values.
The object must be defined in a table indexed only by ifIndex.
All of the instance portion of the object identifier is
trun… | column | ObjectIdentifier | .1.3.6.1.4.1.9.9.218.1.1.5.1.3 |
| cifthThresholdSeverity This object specifies the severity associated with the
condition when the threshold is exceeded. | column | CifthThresholdSeverity | .1.3.6.1.4.1.9.9.218.1.1.5.1.4 |
| cifthThresholdType The manner in which to compare cifthThresholdObject to
cifthThresholdFiredValue and cifthThresholdClearedValue.
The value 'absoluteValue' indicates that the value o… | column | Enumeration | .1.3.6.1.4.1.9.9.218.1.1.5.1.5 |
| cifthThresholdFiredValue A threshold value to check against the object identified in
cifthThresholdObject. If the value of cifthThresholdDirection
is 'rising', then the threshold is fired when the curren… | column | Integer32 | .1.3.6.1.4.1.9.9.218.1.1.5.1.7 |
| cifthThresholdClearedValue A threshold value to check against the object identified in
cifthThresholdObject. If the value of cifthThresholdDirection
is 'rising', then the threshold is cleared when the curr… | column | Integer32 | .1.3.6.1.4.1.9.9.218.1.1.5.1.8 |
| cifthThresholdSampleInterval The number of milliseconds to wait between samples of the
object identified in cifthThresholdObject. To encourage
consistency in sampling, the interval is measured from the
begin… | column | milliseconds Unsigned32 | .1.3.6.1.4.1.9.9.218.1.1.5.1.9 |