cfprQosclassEthClassifiedAdminState
CISCO-FIREPOWER-QOSCLASS-MIB ·
.1.3.6.1.4.1.9.9.826.1.67.6.1.4
Object
column
CISCO-FIREPOWER-TC-MIBCfprQosclassEthClassifiedAdminState
Cisco Firepower qosclass:EthClassified:adminState managed object property
Context
- MIB
- CISCO-FIREPOWER-QOSCLASS-MIB
- OID
.1.3.6.1.4.1.9.9.826.1.67.6.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cfprQosclassEthClassifiedEntry
- Table
- cfprQosclassEthClassifiedTable
- Siblings
- 11
Syntax
CISCO-FIREPOWER-TC-MIBCfprQosclassEthClassifiedAdminState
- Source
- CISCO-FIREPOWER-TC-MIBCfprQosclassEthClassifiedAdminState
- Base type
Enumeration
Values & Constraints
Type Values
0 | disabled |
1 | enabled |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfprQosclassEthClassifiedInstanceId Instance identifier of the managed object. | column | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.67.6.1.1 |
| cfprQosclassEthClassifiedName Cisco Firepower qosclass:EthClassified:name managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.67.6.1.10 |
| cfprQosclassEthClassifiedPriority Cisco Firepower qosclass:EthClassified:priority
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprQosclassEthClassifiedPriority | .1.3.6.1.4.1.9.9.826.1.67.6.1.11 |
| cfprQosclassEthClassifiedWeight Cisco Firepower qosclass:EthClassified:weight
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.67.6.1.12 |
| cfprQosclassEthClassifiedDn Cisco Firepower qosclass:EthClassified:dn managed
object property | column | CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.67.6.1.2 |
| cfprQosclassEthClassifiedRn Cisco Firepower qosclass:EthClassified:rn managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.67.6.1.3 |
| cfprQosclassEthClassifiedBwPercent Cisco Firepower qosclass:EthClassified:bwPercent
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.67.6.1.5 |
| cfprQosclassEthClassifiedCos Cisco Firepower qosclass:EthClassified:cos managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.67.6.1.6 |
| cfprQosclassEthClassifiedDrop Cisco Firepower qosclass:EthClassified:drop managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprQosclassEthClassifiedDrop | .1.3.6.1.4.1.9.9.826.1.67.6.1.7 |
| cfprQosclassEthClassifiedMtu Cisco Firepower qosclass:EthClassified:mtu managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.67.6.1.8 |
| cfprQosclassEthClassifiedMulticastOptimize Cisco Firepower qosclass:EthClassified:multicastOptimize
managed object property | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.826.1.67.6.1.9 |