cfprFabricComputeSlotEpEntry
CISCO-FIREPOWER-FABRIC-MIB ·
.1.3.6.1.4.1.9.9.826.1.26.9.1
Object
row
Entry for the cfprFabricComputeSlotEpTable table.
Context
- MIB
- CISCO-FIREPOWER-FABRIC-MIB
- OID
.1.3.6.1.4.1.9.9.826.1.26.9.1- Type
- row
- Status
- current
- Parent
- cfprFabricComputeSlotEpTable
- Table
- cfprFabricComputeSlotEpTable
- Children
- 54
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfprFabricComputeSlotEpInstanceId Instance identifier of the managed object. | column | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.26.9.1.1 |
| cfprFabricComputeSlotEpDiscovery Cisco Firepower fabric:ComputeSlotEp:discovery
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprComputeDiscovery | .1.3.6.1.4.1.9.9.826.1.26.9.1.10 |
| cfprFabricComputeSlotEpEpDn Cisco Firepower fabric:ComputeSlotEp:epDn managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.11 |
| cfprFabricComputeSlotEpFactoryResetFlag Cisco Firepower fabric:ComputeSlotEp:factoryResetFlag
managed object property | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.826.1.26.9.1.12 |
| cfprFabricComputeSlotEpFltAggr Cisco Firepower fabric:ComputeSlotEp:fltAggr managed
object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.26.9.1.13 |
| cfprFabricComputeSlotEpFruIdentTrigTs Cisco Firepower fabric:ComputeSlotEp:fruIdentTrigTs
managed object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.26.9.1.14 |
| cfprFabricComputeSlotEpFsmDescr Cisco Firepower fabric:ComputeSlotEp:fsmDescr
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.15 |
| cfprFabricComputeSlotEpFsmPrev Cisco Firepower fabric:ComputeSlotEp:fsmPrev managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.16 |
| cfprFabricComputeSlotEpFsmProgr Cisco Firepower fabric:ComputeSlotEp:fsmProgr
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.17 |
| cfprFabricComputeSlotEpFsmRmtInvErrCode Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvErrCode
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.18 |
| cfprFabricComputeSlotEpFsmRmtInvErrDescr Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvErrDescr
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.19 |
| cfprFabricComputeSlotEpDn Cisco Firepower fabric:ComputeSlotEp:dn managed object property | column | CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.26.9.1.2 |
| cfprFabricComputeSlotEpFsmRmtInvRslt Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvRslt
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt | .1.3.6.1.4.1.9.9.826.1.26.9.1.20 |
| cfprFabricComputeSlotEpFsmStageDescr Cisco Firepower fabric:ComputeSlotEp:fsmStageDescr
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.21 |
| cfprFabricComputeSlotEpFsmStamp Cisco Firepower fabric:ComputeSlotEp:fsmStamp
managed object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.826.1.26.9.1.22 |
| cfprFabricComputeSlotEpFsmStatus Cisco Firepower fabric:ComputeSlotEp:fsmStatus
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.23 |
| cfprFabricComputeSlotEpFsmTry Cisco Firepower fabric:ComputeSlotEp:fsmTry managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.24 |
| cfprFabricComputeSlotEpIfRole Cisco Firepower fabric:ComputeSlotEp:ifRole managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricComputeEpIfRole | .1.3.6.1.4.1.9.9.826.1.26.9.1.25 |
| cfprFabricComputeSlotEpIfType Cisco Firepower fabric:ComputeSlotEp:ifType managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricPIoEpIfType | .1.3.6.1.4.1.9.9.826.1.26.9.1.26 |
| cfprFabricComputeSlotEpLcTs Cisco Firepower fabric:ComputeSlotEp:lcTs managed
object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.826.1.26.9.1.27 |
| cfprFabricComputeSlotEpLicGP Cisco Firepower fabric:ComputeSlotEp:licGP managed
object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.26.9.1.28 |
| cfprFabricComputeSlotEpLicState Cisco Firepower fabric:ComputeSlotEp:licState
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprLicenseState | .1.3.6.1.4.1.9.9.826.1.26.9.1.29 |
| cfprFabricComputeSlotEpRn Cisco Firepower fabric:ComputeSlotEp:rn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.3 |
| cfprFabricComputeSlotEpLocale Cisco Firepower fabric:ComputeSlotEp:locale managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricInternalEpLocale | .1.3.6.1.4.1.9.9.826.1.26.9.1.30 |
| cfprFabricComputeSlotEpManagingInst Cisco Firepower fabric:ComputeSlotEp:managingInst
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId | .1.3.6.1.4.1.9.9.826.1.26.9.1.31 |
| cfprFabricComputeSlotEpModel Cisco Firepower fabric:ComputeSlotEp:model managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.32 |
| cfprFabricComputeSlotEpName Cisco Firepower fabric:ComputeSlotEp:name managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.33 |
| cfprFabricComputeSlotEpOperState Cisco Firepower fabric:ComputeSlotEp:operState
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricPIoEpOperState | .1.3.6.1.4.1.9.9.826.1.26.9.1.34 |
| cfprFabricComputeSlotEpOperStateReason Cisco Firepower fabric:ComputeSlotEp:operStateReason
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.35 |
| cfprFabricComputeSlotEpPeerAggrPortId Cisco Firepower fabric:ComputeSlotEp:peerAggrPortId
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.36 |
| cfprFabricComputeSlotEpPeerChassisId Cisco Firepower fabric:ComputeSlotEp:peerChassisId
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.37 |
| cfprFabricComputeSlotEpPeerDn Cisco Firepower fabric:ComputeSlotEp:peerDn managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.38 |
| cfprFabricComputeSlotEpPeerPortId Cisco Firepower fabric:ComputeSlotEp:peerPortId
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.39 |
| cfprFabricComputeSlotEpAdminState Cisco Firepower fabric:ComputeSlotEp:adminState
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricSlotAdminState | .1.3.6.1.4.1.9.9.826.1.26.9.1.4 |
| cfprFabricComputeSlotEpPeerSlotEpDn Cisco Firepower fabric:ComputeSlotEp:peerSlotEpDn
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.40 |
| cfprFabricComputeSlotEpPeerSlotId Cisco Firepower fabric:ComputeSlotEp:peerSlotId
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.41 |
| cfprFabricComputeSlotEpPortId Cisco Firepower fabric:ComputeSlotEp:portId managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricPIoEpPortId | .1.3.6.1.4.1.9.9.826.1.26.9.1.42 |
| cfprFabricComputeSlotEpPresence Cisco Firepower fabric:ComputeSlotEp:presence
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentSlotStatus | .1.3.6.1.4.1.9.9.826.1.26.9.1.43 |
| cfprFabricComputeSlotEpPresencePath Cisco Firepower fabric:ComputeSlotEp:presencePath
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus | .1.3.6.1.4.1.9.9.826.1.26.9.1.44 |
| cfprFabricComputeSlotEpRevision Cisco Firepower fabric:ComputeSlotEp:revision
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.45 |
| cfprFabricComputeSlotEpSerial Cisco Firepower fabric:ComputeSlotEp:serial managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.46 |
| cfprFabricComputeSlotEpSlotId Cisco Firepower fabric:ComputeSlotEp:slotId managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricComputeSlotEpSlotId | .1.3.6.1.4.1.9.9.826.1.26.9.1.47 |
| cfprFabricComputeSlotEpSwitchId Cisco Firepower fabric:ComputeSlotEp:switchId
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId | .1.3.6.1.4.1.9.9.826.1.26.9.1.48 |
| cfprFabricComputeSlotEpTransport Cisco Firepower fabric:ComputeSlotEp:transport
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkTransport | .1.3.6.1.4.1.9.9.826.1.26.9.1.49 |
| cfprFabricComputeSlotEpAggrPortId Cisco Firepower fabric:ComputeSlotEp:aggrPortId
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.5 |
| cfprFabricComputeSlotEpType Cisco Firepower fabric:ComputeSlotEp:type managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprFabricComputeEpType | .1.3.6.1.4.1.9.9.826.1.26.9.1.50 |
| cfprFabricComputeSlotEpVendor Cisco Firepower fabric:ComputeSlotEp:vendor managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.51 |
| cfprFabricComputeSlotEpBladeState Cisco Firepower fabric:ComputeSlotEp:bladeState
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprLsOperState | .1.3.6.1.4.1.9.9.826.1.26.9.1.52 |
| cfprFabricComputeSlotEpDecommissionSecure Cisco Firepower fabric:ComputeSlotEp:decommissionSecure
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprComputeDecommissionState | .1.3.6.1.4.1.9.9.826.1.26.9.1.53 |
| cfprFabricComputeSlotEpFailReason Cisco Firepower fabric:ComputeSlotEp:failReason
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.26.9.1.54 |
| cfprFabricComputeSlotEpBoardAggregationRole Cisco Firepower fabric:ComputeSlotEp:boardAggregationRole
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentBoardAggregationRole | .1.3.6.1.4.1.9.9.826.1.26.9.1.6 |
| cfprFabricComputeSlotEpChassisId Cisco Firepower fabric:ComputeSlotEp:chassisId
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.26.9.1.7 |
| cfprFabricComputeSlotEpConnPath Cisco Firepower fabric:ComputeSlotEp:connPath
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus | .1.3.6.1.4.1.9.9.826.1.26.9.1.8 |
| cfprFabricComputeSlotEpConnStatus Cisco Firepower fabric:ComputeSlotEp:connStatus
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus | .1.3.6.1.4.1.9.9.826.1.26.9.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfprFabricComputeSlotEpInstanceId Instance identifier of the managed object. | column | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.26.9.1.1 |