cfprEquipmentIOCardSwitchId
CISCO-FIREPOWER-EQUIPMENT-MIB ·
.1.3.6.1.4.1.9.9.826.1.20.62.1.42
Object
column
CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId
Cisco Firepower equipment:IOCard:switchId managed object property
Context
- MIB
- CISCO-FIREPOWER-EQUIPMENT-MIB
- OID
.1.3.6.1.4.1.9.9.826.1.20.62.1.42- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cfprEquipmentIOCardEntry
- Table
- cfprEquipmentIOCardTable
- Siblings
- 47
Syntax
CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId
- Source
- CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId
- Base type
Enumeration
Values & Constraints
Type Values
0 | none |
1 | a |
2 | b |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfprEquipmentIOCardInstanceId Instance identifier of the managed object. | column | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.20.62.1.1 |
| cfprEquipmentIOCardFeReadyTs Cisco Firepower equipment:IOCard:feReadyTs managed
object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.20.62.1.10 |
| cfprEquipmentIOCardFltAggr Cisco Firepower equipment:IOCard:fltAggr managed object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.20.62.1.11 |
| cfprEquipmentIOCardFsmDescr Cisco Firepower equipment:IOCard:fsmDescr managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.12 |
| cfprEquipmentIOCardFsmFlags Cisco Firepower equipment:IOCard:fsmFlags managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.13 |
| cfprEquipmentIOCardFsmPrev Cisco Firepower equipment:IOCard:fsmPrev managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.14 |
| cfprEquipmentIOCardFsmProgr Cisco Firepower equipment:IOCard:fsmProgr managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.20.62.1.15 |
| cfprEquipmentIOCardFsmRmtInvErrCode Cisco Firepower equipment:IOCard:fsmRmtInvErrCode
managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.20.62.1.16 |
| cfprEquipmentIOCardFsmRmtInvErrDescr Cisco Firepower equipment:IOCard:fsmRmtInvErrDescr
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.17 |
| cfprEquipmentIOCardFsmRmtInvRslt Cisco Firepower equipment:IOCard:fsmRmtInvRslt
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt | .1.3.6.1.4.1.9.9.826.1.20.62.1.18 |
| cfprEquipmentIOCardFsmStageDescr Cisco Firepower equipment:IOCard:fsmStageDescr
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.19 |
| cfprEquipmentIOCardDn Cisco Firepower equipment:IOCard:dn managed object property | column | CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.20.62.1.2 |
| cfprEquipmentIOCardFsmStamp Cisco Firepower equipment:IOCard:fsmStamp managed
object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.826.1.20.62.1.20 |
| cfprEquipmentIOCardFsmStatus Cisco Firepower equipment:IOCard:fsmStatus managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.21 |
| cfprEquipmentIOCardFsmTry Cisco Firepower equipment:IOCard:fsmTry managed object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.20.62.1.22 |
| cfprEquipmentIOCardId Cisco Firepower equipment:IOCard:id managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentIOCardId | .1.3.6.1.4.1.9.9.826.1.20.62.1.23 |
| cfprEquipmentIOCardLcName Cisco Firepower equipment:IOCard:lcName managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.24 |
| cfprEquipmentIOCardLcTs Cisco Firepower equipment:IOCard:lcTs managed object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.826.1.20.62.1.25 |
| cfprEquipmentIOCardMfgTime Cisco Firepower equipment:IOCard:mfgTime managed object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.826.1.20.62.1.26 |
| cfprEquipmentIOCardModel Cisco Firepower equipment:IOCard:model managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.27 |
| cfprEquipmentIOCardOperQualifier Cisco Firepower equipment:IOCard:operQualifier
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentIOCardIssues | .1.3.6.1.4.1.9.9.826.1.20.62.1.28 |
| cfprEquipmentIOCardOperQualifierReason Cisco Firepower equipment:IOCard:operQualifierReason
managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.29 |
| cfprEquipmentIOCardRn Cisco Firepower equipment:IOCard:rn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.3 |
| cfprEquipmentIOCardOperState Cisco Firepower equipment:IOCard:operState managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability | .1.3.6.1.4.1.9.9.826.1.20.62.1.30 |
| cfprEquipmentIOCardOperability Cisco Firepower equipment:IOCard:operability managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability | .1.3.6.1.4.1.9.9.826.1.20.62.1.31 |
| cfprEquipmentIOCardPartNumber Cisco Firepower equipment:IOCard:partNumber managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.32 |
| cfprEquipmentIOCardPeerCommStatus Cisco Firepower equipment:IOCard:peerCommStatus
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentCommStatus | .1.3.6.1.4.1.9.9.826.1.20.62.1.33 |
| cfprEquipmentIOCardPeerDn Cisco Firepower equipment:IOCard:peerDn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.34 |
| cfprEquipmentIOCardPerf Cisco Firepower equipment:IOCard:perf managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus | .1.3.6.1.4.1.9.9.826.1.20.62.1.35 |
| cfprEquipmentIOCardPower Cisco Firepower equipment:IOCard:power managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentPowerState | .1.3.6.1.4.1.9.9.826.1.20.62.1.36 |
| cfprEquipmentIOCardPresence Cisco Firepower equipment:IOCard:presence managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentPresence | .1.3.6.1.4.1.9.9.826.1.20.62.1.37 |
| cfprEquipmentIOCardProcessorThermalState Cisco Firepower equipment:IOCard:processorThermalState
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus | .1.3.6.1.4.1.9.9.826.1.20.62.1.38 |
| cfprEquipmentIOCardRevision Cisco Firepower equipment:IOCard:revision managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.39 |
| cfprEquipmentIOCardAdminPowerState Cisco Firepower equipment:IOCard:adminPowerState
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentAdminPowerState | .1.3.6.1.4.1.9.9.826.1.20.62.1.4 |
| cfprEquipmentIOCardSerial Cisco Firepower equipment:IOCard:serial managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.40 |
| cfprEquipmentIOCardSide Cisco Firepower equipment:IOCard:side managed object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkSide | .1.3.6.1.4.1.9.9.826.1.20.62.1.41 |
| cfprEquipmentIOCardThermal Cisco Firepower equipment:IOCard:thermal managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus | .1.3.6.1.4.1.9.9.826.1.20.62.1.43 |
| cfprEquipmentIOCardUpgradeStatus Cisco Firepower equipment:IOCard:upgradeStatus
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprMgmtUpgradeStatus | .1.3.6.1.4.1.9.9.826.1.20.62.1.44 |
| cfprEquipmentIOCardUsrLbl Cisco Firepower equipment:IOCard:usrLbl managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.45 |
| cfprEquipmentIOCardVendor Cisco Firepower equipment:IOCard:vendor managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.46 |
| cfprEquipmentIOCardVid Cisco Firepower equipment:IOCard:vid managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.62.1.47 |
| cfprEquipmentIOCardVoltage Cisco Firepower equipment:IOCard:voltage managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus | .1.3.6.1.4.1.9.9.826.1.20.62.1.48 |
| cfprEquipmentIOCardBaseAddr Cisco Firepower equipment:IOCard:baseAddr managed
object property | column | INET-ADDRESS-MIBInetAddressIPv4 | .1.3.6.1.4.1.9.9.826.1.20.62.1.5 |
| cfprEquipmentIOCardChassisId Cisco Firepower equipment:IOCard:chassisId managed
object property | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.826.1.20.62.1.6 |
| cfprEquipmentIOCardConfigState Cisco Firepower equipment:IOCard:configState managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentChassisConfigState | .1.3.6.1.4.1.9.9.826.1.20.62.1.7 |
| cfprEquipmentIOCardDiscovery Cisco Firepower equipment:IOCard:discovery managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentDiscoveryState | .1.3.6.1.4.1.9.9.826.1.20.62.1.8 |
| cfprEquipmentIOCardFeOfflineTs Cisco Firepower equipment:IOCard:feOfflineTs managed
object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.20.62.1.9 |