cfprEquipmentIOCardStatsHistProcTempAvg
CISCO-FIREPOWER-EQUIPMENT-MIB ·
.1.3.6.1.4.1.9.9.826.1.20.71.1.15
Object
column
Integer32
Cisco Firepower equipment:IOCardStatsHist:procTempAvg managed object property
Context
- MIB
- CISCO-FIREPOWER-EQUIPMENT-MIB
- OID
.1.3.6.1.4.1.9.9.826.1.20.71.1.15- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cfprEquipmentIOCardStatsHistEntry
- Table
- cfprEquipmentIOCardStatsHistTable
- Siblings
- 23
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfprEquipmentIOCardStatsHistInstanceId Instance identifier of the managed object. | column | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.20.71.1.1 |
| cfprEquipmentIOCardStatsHistDimmTempMax Cisco Firepower equipment:IOCardStatsHist:dimmTempMax
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.10 |
| cfprEquipmentIOCardStatsHistDimmTempMin Cisco Firepower equipment:IOCardStatsHist:dimmTempMin
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.11 |
| cfprEquipmentIOCardStatsHistId Cisco Firepower equipment:IOCardStatsHist:id managed
object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.20.71.1.12 |
| cfprEquipmentIOCardStatsHistMostRecent Cisco Firepower equipment:IOCardStatsHist:mostRecent
managed object property | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.826.1.20.71.1.13 |
| cfprEquipmentIOCardStatsHistProcTemp Cisco Firepower equipment:IOCardStatsHist:procTemp
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.14 |
| cfprEquipmentIOCardStatsHistProcTempMax Cisco Firepower equipment:IOCardStatsHist:procTempMax
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.16 |
| cfprEquipmentIOCardStatsHistProcTempMin Cisco Firepower equipment:IOCardStatsHist:procTempMin
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.17 |
| cfprEquipmentIOCardStatsHistSuspect Cisco Firepower equipment:IOCardStatsHist:suspect
managed object property | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.9.826.1.20.71.1.18 |
| cfprEquipmentIOCardStatsHistTemp Cisco Firepower equipment:IOCardStatsHist:temp
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.19 |
| cfprEquipmentIOCardStatsHistDn Cisco Firepower equipment:IOCardStatsHist:dn managed
object property | column | CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.20.71.1.2 |
| cfprEquipmentIOCardStatsHistTempAvg Cisco Firepower equipment:IOCardStatsHist:tempAvg
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.20 |
| cfprEquipmentIOCardStatsHistTempMax Cisco Firepower equipment:IOCardStatsHist:tempMax
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.21 |
| cfprEquipmentIOCardStatsHistTempMin Cisco Firepower equipment:IOCardStatsHist:tempMin
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.22 |
| cfprEquipmentIOCardStatsHistThresholded Cisco Firepower equipment:IOCardStatsHist:thresholded
managed object property | column | CISCO-FIREPOWER-TC-MIBCfprEquipmentIOCardStatsHistThresholded | .1.3.6.1.4.1.9.9.826.1.20.71.1.23 |
| cfprEquipmentIOCardStatsHistTimeCollected Cisco Firepower equipment:IOCardStatsHist:timeCollected
managed object property | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.9.9.826.1.20.71.1.24 |
| cfprEquipmentIOCardStatsHistRn Cisco Firepower equipment:IOCardStatsHist:rn managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.20.71.1.3 |
| cfprEquipmentIOCardStatsHistAmbientTemp Cisco Firepower equipment:IOCardStatsHist:ambientTemp
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.4 |
| cfprEquipmentIOCardStatsHistAmbientTempAvg Cisco Firepower equipment:IOCardStatsHist:ambientTempAvg
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.5 |
| cfprEquipmentIOCardStatsHistAmbientTempMax Cisco Firepower equipment:IOCardStatsHist:ambientTempMax
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.6 |
| cfprEquipmentIOCardStatsHistAmbientTempMin Cisco Firepower equipment:IOCardStatsHist:ambientTempMin
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.7 |
| cfprEquipmentIOCardStatsHistDimmTemp Cisco Firepower equipment:IOCardStatsHist:dimmTemp
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.8 |
| cfprEquipmentIOCardStatsHistDimmTempAvg Cisco Firepower equipment:IOCardStatsHist:dimmTempAvg
managed object property | column | Integer32 | .1.3.6.1.4.1.9.9.826.1.20.71.1.9 |