cfprAdaptorExtEthIfPcEntry
CISCO-FIREPOWER-ADAPTOR-MIB ·
.1.3.6.1.4.1.9.9.826.1.3.32.1
Object
row
Entry for the cfprAdaptorExtEthIfPcTable table.
Context
- MIB
- CISCO-FIREPOWER-ADAPTOR-MIB
- OID
.1.3.6.1.4.1.9.9.826.1.3.32.1- Type
- row
- Status
- current
- Parent
- cfprAdaptorExtEthIfPcTable
- Table
- cfprAdaptorExtEthIfPcTable
- Children
- 18
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfprAdaptorExtEthIfPcInstanceId Instance identifier of the managed object. | column | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.3.32.1.1 |
| cfprAdaptorExtEthIfPcName Cisco Firepower adaptor:ExtEthIfPc:name managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.3.32.1.10 |
| cfprAdaptorExtEthIfPcOperSpeed Cisco Firepower adaptor:ExtEthIfPc:operSpeed managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprPortEthSpeed | .1.3.6.1.4.1.9.9.826.1.3.32.1.11 |
| cfprAdaptorExtEthIfPcOperState Cisco Firepower adaptor:ExtEthIfPc:operState managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkPortOperState | .1.3.6.1.4.1.9.9.826.1.3.32.1.12 |
| cfprAdaptorExtEthIfPcPeerDn Cisco Firepower adaptor:ExtEthIfPc:peerDn managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.3.32.1.13 |
| cfprAdaptorExtEthIfPcPortId Cisco Firepower adaptor:ExtEthIfPc:portId managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprAdaptorExtEthIfPcPortId | .1.3.6.1.4.1.9.9.826.1.3.32.1.14 |
| cfprAdaptorExtEthIfPcStateQual Cisco Firepower adaptor:ExtEthIfPc:stateQual managed
object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.3.32.1.15 |
| cfprAdaptorExtEthIfPcSwitchId Cisco Firepower adaptor:ExtEthIfPc:switchId managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId | .1.3.6.1.4.1.9.9.826.1.3.32.1.16 |
| cfprAdaptorExtEthIfPcTransport Cisco Firepower adaptor:ExtEthIfPc:transport managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprAdaptorExtEthIfPcTransport | .1.3.6.1.4.1.9.9.826.1.3.32.1.17 |
| cfprAdaptorExtEthIfPcType Cisco Firepower adaptor:ExtEthIfPc:type managed object property | column | CISCO-FIREPOWER-TC-MIBCfprAdaptorExtIfPcType | .1.3.6.1.4.1.9.9.826.1.3.32.1.18 |
| cfprAdaptorExtEthIfPcDn Cisco Firepower adaptor:ExtEthIfPc:dn managed object property | column | CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.3.32.1.2 |
| cfprAdaptorExtEthIfPcRn Cisco Firepower adaptor:ExtEthIfPc:rn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.3.32.1.3 |
| cfprAdaptorExtEthIfPcEpDn Cisco Firepower adaptor:ExtEthIfPc:epDn managed object property | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.9.9.826.1.3.32.1.4 |
| cfprAdaptorExtEthIfPcFltAggr Cisco Firepower adaptor:ExtEthIfPc:fltAggr managed
object property | column | CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.3.32.1.5 |
| cfprAdaptorExtEthIfPcIfRole Cisco Firepower adaptor:ExtEthIfPc:ifRole managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprAdaptorExtIfPcIfRole | .1.3.6.1.4.1.9.9.826.1.3.32.1.6 |
| cfprAdaptorExtEthIfPcIfType Cisco Firepower adaptor:ExtEthIfPc:ifType managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprAdaptorCIoEpIfType | .1.3.6.1.4.1.9.9.826.1.3.32.1.7 |
| cfprAdaptorExtEthIfPcLocale Cisco Firepower adaptor:ExtEthIfPc:locale managed
object property | column | CISCO-FIREPOWER-TC-MIBCfprAdaptorExternalPcLocale | .1.3.6.1.4.1.9.9.826.1.3.32.1.8 |
| cfprAdaptorExtEthIfPcMac Cisco Firepower adaptor:ExtEthIfPc:mac managed object property | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.9.9.826.1.3.32.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfprAdaptorExtEthIfPcInstanceId Instance identifier of the managed object. | column | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.3.32.1.1 |