cFcSdvVdAssignedFcId
CISCO-FC-SDV-MIB ·
.1.3.6.1.4.1.9.9.593.1.1.1.1.7
Object
column
CISCO-ST-TCFcAddressId
The assigned 'FCID' of this Virtual Device. The agent assigns this value when the configuration is committed and the Real Device that this Virtual Device virtualizes (corresponding entry in the cFcSdvVirtRealDevMapTable where the value of cFcSdvVirtRealDevMapType is 'primaryDevMap') is on-line.
Context
- MIB
- CISCO-FC-SDV-MIB
- OID
.1.3.6.1.4.1.9.9.593.1.1.1.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cFcSdvVirtDeviceEntry
- Table
- cFcSdvVirtDeviceTable
- Siblings
- 9
Syntax
CISCO-ST-TCFcAddressId
- Source
- CISCO-ST-TCFcAddressId
- Base type
OctetString
Values & Constraints
Type Constraints
range: 3
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cFcSdvVdIndex An arbitrary index number of a Virtual Device.
This instance value uniquely identifies a Virtual
Device within the context of a particular VSAN and
in the agent where an instance … | column | Unsigned32 | .1.3.6.1.4.1.9.9.593.1.1.1.1.1 |
| cFcSdvVdRowStatus The status of this conceptual row. The value of
this object can not be set to 'active' unless the
value of the corresponding instance of cFcSdvVdName
is unique across all the VSAN… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.9.9.593.1.1.1.1.10 |
| cFcSdvVdName A human readable string representing the name of
this Virtual Device. The value of cFcSdvVdName
should be unique in the system. | column | OctetString | .1.3.6.1.4.1.9.9.593.1.1.1.1.2 |
| cFcSdvVdVirtDomain The user preference for a persistent Domain Id
for this Virtual Device to indicate a specific
partition (domain) of the Fabric that this
Virtual Device should belong to.
… | column | CISCO-ST-TCDomainIdOrZero | .1.3.6.1.4.1.9.9.593.1.1.1.1.3 |
| cFcSdvVdFcId The user preference for a persistent 'FCID' for
this Virtual Device.
The value of the corresponding instance of
cFcSdvVdVirtDomain specifies the Domain identifier… | column | CISCO-ST-TCFcAddressId | .1.3.6.1.4.1.9.9.593.1.1.1.1.4 |
| cFcSdvVdPwwn The assigned 'PWWN' for this Virtual Device.
The agent assigns this value when the
configuration is committed. | column | CISCO-ST-TCFcNameIdOrZero | .1.3.6.1.4.1.9.9.593.1.1.1.1.5 |
| cFcSdvVdNwwn The assigned 'NWWN' for this Virtual Device.
The agent assigns this value when the
configuration is committed. | column | CISCO-ST-TCFcNameIdOrZero | .1.3.6.1.4.1.9.9.593.1.1.1.1.6 |
| cFcSdvVdRealDevMapList The set of Real Device(s) that this Virtual Device
virtualizes in this VSAN.
The Real Devices are identified by the instance
identifier object cFcSdvVirtRealDevMap… | column | OctetString | .1.3.6.1.4.1.9.9.593.1.1.1.1.8 |
| cFcSdvVdStorageType The storage type for this conceptual row.
Conceptual rows having the value of this object as
'readOnly' can not be deleted by the user by setting
the value of cFcS… | column | SNMPv2-TCStorageType | .1.3.6.1.4.1.9.9.593.1.1.1.1.9 |