mrStackReset

CISCO-FASTHUB-MIB · .1.3.6.1.4.1.9.2.11.1.1.5

Object

scalar mandatory r/w Enumeration
reset(1)       -- reset
noReset(2),    -- do nothing
          
A write to this object with reset(1) causes a complete
reset of the repeater hardware and the Supervisor but
does not run the POST. All FastHub configuration
parameters are retained and all network related statistics
in the system are cleared. Setting this object to
noReset(2) has no effect. FastHub will always return
noReset(2) when this object is read.

Context

MIB
CISCO-FASTHUB-MIB
OID
.1.3.6.1.4.1.9.2.11.1.1.5
Type
scalar
Access
readwrite
Status
mandatory
Parent
mrStack
Siblings
7

Syntax

Enumeration

Values & Constraints

Enumerated Values
1reset
2noReset

Related Objects

Sibling Objects