ceAlarmNotifiesEnable

CISCO-ENTITY-ALARM-MIB · .1.3.6.1.4.1.9.9.138.1.4.1

Object

scalar r/w AlarmSeverityOrZero
This object specifies a severity threshold governing the
generation of ceAlarmAsserted and ceAlarmCleared
notifications.  For example, if the value of this object is
set to 'major', then the agent generates these notifications
if and only if the severity of the alarm being indicated is
'major' or 'critical'.  The value of '0' disables the 
generation of notifications.
          
Observe that this setting overrides the value of the 
ceAlarmFilterNotifiesEnabled object.
          
This object affects notification generation only; that is, it
does not affect monitoring, history logging, and syslog message
generation.

Context

MIB
CISCO-ENTITY-ALARM-MIB
OID
.1.3.6.1.4.1.9.9.138.1.4.1
Type
scalar
Access
readwrite
Status
current
Parent
ceAlarmFiltering
Siblings
3

Syntax

AlarmSeverityOrZero
Source
AlarmSeverityOrZero
Base type
Integer32

Values & Constraints

Type Constraints
range: 0..4

Related Objects

Sibling Objects