cdot3OamErrSymPeriodWindowLo
CISCO-DOT3-OAM-MIB ·
.1.3.6.1.4.1.9.10.136.1.5.1.2
Object
The two objects cdot3OamErrSymPeriodWindowHi and
cdot3OamErrSymPeriodWindowLo together form an unsigned 64-bit
integer representing the number of symbols over which this
threshold event is defined. This is defined as
cdot3OamErrSymPeriodWindow = ((2^32)*cdot3OamErrSymPeriodWindowHi)
+ cdot3OamErrSymPeriodWindowLo
If cdot3OamErrSymPeriodThreshold symbol errors occur within a
window of cdot3OamErrSymPeriodWindow symbols, an Event
Notification OAMPDU should be generated with an Errored Symbol
Period Event TLV indicating the threshold has been crossed in
this window.
The default value for cdot3OamErrSymPeriodWindow is the number
of symbols in one second for the underlying physical layer.
Context
- MIB
- CISCO-DOT3-OAM-MIB
- OID
.1.3.6.1.4.1.9.10.136.1.5.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Units
- symbols
- Parent
- cdot3OamEventConfigEntry
- Table
- cdot3OamEventConfigTable
- Siblings
- 15
Syntax
symbols SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cdot3OamErrSymPeriodWindowHi The two objects cdot3OamErrSymPeriodWindowHi and
cdot3OamErrSymPeriodLo together form an unsigned 64-bit
integer representing the number of symbols over which this
threshold event… | column | 2^32 symbols SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.10.136.1.5.1.1 |
| cdot3OamErrFrameThreshold The number of frame errors that must occur for this event to
be triggered. The default value is one frame error. If the
threshold value is zero, then an Event Notification OAMPDU… | column | frames SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.10.136.1.5.1.10 |
| cdot3OamErrFrameEvNotifEnable If true, the OAM entity should send an Event Notification
OAMPDU when an Errored Frame Event occurs.
By default, this object should have the value … | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.136.1.5.1.11 |
| cdot3OamErrFrameSecsSummaryWindow The amount of time (in 100ms intervals) over which the
threshold is defined. The default value is 100 (10 seconds).
If cdot3OamErrFrameSecsSummar… | column | tenths of a second Integer32 | .1.3.6.1.4.1.9.10.136.1.5.1.12 |
| cdot3OamErrFrameSecsSummaryThreshold The number of errored frame seconds that must occur for this
event to be triggered. The default value is one errored frame
second. If the threshold value is zero, then an Event
N… | column | errored frame seconds Integer32 | .1.3.6.1.4.1.9.10.136.1.5.1.13 |
| cdot3OamErrFrameSecsEvNotifEnable If true, the local OAM entity should send an Event
Notification OAMPDU when an Errored Frame Seconds Event
occurs.
By default, this object should h… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.136.1.5.1.14 |
| cdot3OamDyingGaspEnable If true, the local OAM entity should attempt to indicate a
dying gasp via the OAMPDU flags field to its peer OAM entity
when a dying gasp event occurs. The exact definition of a
… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.136.1.5.1.15 |
| cdot3OamCriticalEventEnable If true, the local OAM entity should attempt to indicate a
critical event via the OAMPDU flags to its peer OAM entity
when a critical event occurs. The exact definition of a
cri… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.136.1.5.1.16 |
| cdot3OamErrSymPeriodThresholdHi The two objects cdot3OamErrSymPeriodThresholdHi and
cdot3OamErrSymPeriodThresholdLo together form an unsigned
64-bit integer representing the number of symbol errors that
must occ… | column | 2^32 symbols SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.10.136.1.5.1.3 |
| cdot3OamErrSymPeriodThresholdLo The two objects cdot3OamErrSymPeriodThresholdHi and
cdot3OamErrSymPeriodThresholdLo together form an unsigned
64-bit integer representing the number of symbol errors that
must occ… | column | symbols SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.10.136.1.5.1.4 |
| cdot3OamErrSymPeriodEvNotifEnable If true, the OAM entity should send an Event Notification
OAMPDU when an Errored Symbol Period Event occurs.
By default, this object should have the value true for
Ethernet like … | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.136.1.5.1.5 |
| cdot3OamErrFramePeriodWindow The number of frames over which the threshold is defined.
The default value of the window is the number of minimum size
Ethernet frames that can be received over the physical laye… | column | frames SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.10.136.1.5.1.6 |
| cdot3OamErrFramePeriodThreshold The number of frame errors that must occur for this event to
be triggered. The default value is one frame error. If the
threshold value is zero, then an Event Notification OAMPD… | column | frames SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.10.136.1.5.1.7 |
| cdot3OamErrFramePeriodEvNotifEnable If true, the OAM entity should send an Event Notification
OAMPDU when an Errored Frame Period Event occurs.
By default, this object should have the value true for
… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9.10.136.1.5.1.8 |
| cdot3OamErrFrameWindow The amount of time (in 100ms increments) over which the
threshold is defined. The default value is 10 (1 second).
If cdot3OamErrFrameThreshold fr… | column | tenths of a second SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9.10.136.1.5.1.9 |