dmFabricChangeNotify
CISCO-DM-MIB ·
.1.3.6.1.4.1.9.9.302.1.3.0.3
Object
notification
This notification is sent whenever a switch sends or
receives a Build Fabric (BF) or a ReConfigure Fabric
(RCF) message on a VSAN.
A switch can receive or issue a BuildFabric (BF) or a
ReConfigureFabric (RCF) message under following
conditions:
- A new link causes two disjoint fabrics in a VSAN to
merge into one fabric. The sent/received message is
BF if the Domain ID lists on the disjoint fabric
does not overlap and it is RCF if they overlap.
- An upsteam principal ISL which connects to Principal
switch and other switches in a VSAN fails. BF is
issued to see if there is an alternative path to
the Principal Switch. If not paths exit, then an RCF
is issued.
- A switch asks for a different set of Domain IDs
than the currently assigned list, the Principal
switch would issue an RCF.
The notification is not sent if a
'dmNewPrincipalSwitchNotify' notification is sent
for the same transition.
This notification contains the vsanIndex of the VSAN
on which RCF was issued.
Context
- MIB
- CISCO-DM-MIB
- OID
.1.3.6.1.4.1.9.9.302.1.3.0.3- Type
- notification
- Status
- current
- Parent
- dmNotification
- Siblings
- 2
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dmDomainIdNotAssignedNotify If a Domain ID is not configured or assigned on a
VSAN, then the switch may isolate E_ports on that
VSAN. The conditions are :
- If the Domain Manager is enabled on the local
sw… | notification | - | .1.3.6.1.4.1.9.9.302.1.3.0.1 |
| dmNewPrincipalSwitchNotify This notification indicates that the sending switch
has become the new Principal Switch on a VSAN. This
notification is sent soon after its election as the
new Principal Switch, i… | notification | - | .1.3.6.1.4.1.9.9.302.1.3.0.2 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| CISCO-VSAN-MIBnotifyVsanIndex The ID of the VSAN.
This object is to be used only as an object in the
notification. We cannot use the vsanIndex in a
notification as it is defined to not-accessible in the
vsa… | scalar | CISCO-ST-TCVsanIndex | .1.3.6.1.4.1.9.9.282.1.1.4 |