cddHostTolCfgEntry
CISCO-DIST-DIRECTOR-MIB ·
.1.3.6.1.4.1.9.9.197.1.2.3.1
Object
row
An entry containing Distributed Director per-host
metrics tolerance information at a priority level. If
at a priority level two or more remote servers have
metric values that are within a certain tolerance
percentage of each other, they are considered to be the
same and thus causing a 'tie'. In this case, the metrics
at the next priority level will be used in order to
break the tie.
For example, the DRP RTT metric is given priority 1 and
the DRP external metric is given priority 2; and the
tolerance percentage value is set to 20 at priority 1.
If server 'A' has the DRP RTT metric value of 100 and
server 'B' has the value of 119, they will be
considered the same because their difference is within
20% of the metric value of server 'A'. Then the DRP
external metric will be used to select the best server.
Entries in this table may be queried, created or
deleted by NMS. Each entry in this table is dependent
on entries in cddHostTable. If the associated entry in
cddHostTable that has the same cddHostName and
cddHostQueryType values is deleted, the entry in this
table is deleted as well.
Context
- MIB
- CISCO-DIST-DIRECTOR-MIB
- OID
.1.3.6.1.4.1.9.9.197.1.2.3.1- Type
- row
- Status
- current
- Parent
- cddHostTolCfgTable
- Table
- cddHostTolCfgTable
- Children
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cddHostTolCfgPrio Specifies the metrics tolerance priority level for the
host. | column | Unsigned32 | .1.3.6.1.4.1.9.9.197.1.2.3.1.1 |
| cddHostTolCfgPerc Specifies the metrics tolerance percentage value
associated with the priority level. | column | percentage Unsigned32 | .1.3.6.1.4.1.9.9.197.1.2.3.1.2 |
| cddHostTolCfgRowStatus The status of the row. This object is used to create
a new row or delete an existing row in this table. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.9.9.197.1.2.3.1.3 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| cddHostName The name of a virtual host or subdomain. | column | DNS-SERVER-MIBDnsNameAsIndex | .1.3.6.1.4.1.9.9.197.1.2.1.1.1 |
| cddHostQueryType The type of DNS query for which this host entry
information would be used. Currently only query type
'A(1)', 'NS(2)', and 'MX(15)' are supported. | column | DNS-SERVER-MIBDnsType | .1.3.6.1.4.1.9.9.197.1.2.1.1.2 |
| cddHostTolCfgPrio Specifies the metrics tolerance priority level for the
host. | column | Unsigned32 | .1.3.6.1.4.1.9.9.197.1.2.3.1.1 |