coCdlDefectIndNotifyEnable

CISCO-CDL-MIB · .1.3.6.1.4.1.9.10.88.1.1.2

Object

scalar r/w Enumeration
This object indicates whether a change in the received CDL
Defect Indications, including the implicit end-to-end path
defect indication as well as the CDL defect indication bits in
the CDL OAM field, causes a notification to be generated.
          
disabled: Received CDL aggregate defect indication bit changes
    do not cause coCdlRxAggDefectIndChange notifications to be
    generated, and CDL flow defect indication changes from the
    CDL network at path terminating interfaces do not cause
    coCdlFromCdlNetFlowDIChange notifications to be generated.
          
enabledAtTerminatingInterfaces: A coCdlRxAggDefectIndChange
    notification is generated whenever
    - the received hop-by-hop forward defect indication (FDI-H)
      or the received hop-by-hop backward defect indication bit
      (BDI-H) changes at a hop terminating interface, or
    - the received end-to-end (aggregate path) defect
      indication bit (FDI-E) changes at an aggregate path
      terminating interface.
    A coCdlFromCdlNetFlowDIChange notification is generated
    whenever a CDL flow defect indication, i.e. implicit
    end-to-end path forward defect indication or end-to-end
    path backward defect indication bit, from the CDL network
    changes at a path terminating interface.
          
enabledAtAllInterfaces: a coCdlRxAggDefectIndChange
    notification is generated whenever a received CDL aggregate
    defect indication bit changes on any interface, and a
    coCdlFromCdlNetFlowDIChange notification is generated
    whenever a CDL flow defect indication, i.e. implicit
    end-to-end path forward defect indication or end-to-end
    path backward defect indication bit, from the CDL network
    changes at a path terminating interface.
          
To minimize the probability of prematurely reacting to
momentary signal variations, a soak time may be incorporated
into the notification in the following manner. A notification
is generated after a defect is first detected, when the defect
persists for a period of time that exceeds the set soak
interval specified by coCdlDefectIndSetSoakInterval. A
notification is generated after a defect stops being detected,
when the defect does not appear over a period of time that
exceeds the clear soak interval specified by
coCdlDefectIndClearSoakInterval.
          
When changes in CDL defect indications are received for
multiple interfaces within a short time span, notifications
should be deferred so that each notification is generated at
least one coCdlDINotifyThrottleInterval after the previous
notification.

Context

MIB
CISCO-CDL-MIB
OID
.1.3.6.1.4.1.9.10.88.1.1.2
Type
scalar
Access
readwrite
Status
current
Parent
coCdlBaseGroup
Siblings
4

Syntax

Enumeration

Values & Constraints

Enumerated Values
1disabled
2enabledAtTerminatingInterfaces
3enabledAtAllInterfaces

Related Objects

Sibling Objects