coCdlDINotifyThrottleInterval
CISCO-CDL-MIB ·
.1.3.6.1.4.1.9.10.88.1.1.5
Object
scalar
r/w
milliseconds Unsigned32
The minimum time interval between generation of successive
CDL defect indication 'notification-events' by this agent. A
'notification-event' is the transmission of a single trap or
inform PDU to a list of notification destinations.
If more than one change occurs within a short time span, for
for example if hop-by-hop forward defect indications are
received for multiple interfaces, then notification-events
for these changes should be deferred by the agent so that each
notification-event occurs at least one throttle interval after
the previous notification-event. At the end of each throttle
interval, one notification-event should be generated if the
current defect indication state on any interface is different
from the last state indicated in a notification-event. In such
a case, another throttle interval is started immediately.
Context
- MIB
- CISCO-CDL-MIB
- OID
.1.3.6.1.4.1.9.10.88.1.1.5- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- coCdlBaseGroup
- Siblings
- 4
Syntax
milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 100-60000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| coCdlIntfTable This table provides objects to configure and monitor CDL on an
Ethernet interface. | table | - | .1.3.6.1.4.1.9.10.88.1.1.1 |
| coCdlDefectIndNotifyEnable This object indicates whether a change in the received CDL
Defect Indications, including the implicit end-to-end path
defect indication as well as the CDL defect indication bits i… | scalar | Enumeration | .1.3.6.1.4.1.9.10.88.1.1.2 |
| coCdlDefectIndSetSoakInterval To minimize the probability of prematurely reacting to
momentary signal variations, a soak time may be incorporated
into the defect indications. The indication is set when the
def… | scalar | milliseconds Unsigned32 | .1.3.6.1.4.1.9.10.88.1.1.3 |
| coCdlDefectIndClearSoakInterval To minimize the probability of prematurely reacting to
momentary signal variations, a soak time may be incorporated
into the defect indications. The indication is cleared when no
… | scalar | milliseconds Unsigned32 | .1.3.6.1.4.1.9.10.88.1.1.4 |