c2900InfoTotalBufferDepth
CISCO-C2900-MIB ·
.1.3.6.1.4.1.9.9.87.1.1.3
Object
It represents the total number of 64-byte buffers in the Ethernet Controller.
Context
- MIB
- CISCO-C2900-MIB
- OID
.1.3.6.1.4.1.9.9.87.1.1.3- Type
- scalar
- Access
- readonly
- Status
- current
- Units
- buffers
- Parent
- c2900SysInfo
- Siblings
- 9
Syntax
buffers SNMPv2-SMIGauge32
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| c2900InfoBoardRevision Returns the revision number of the main board
on which the FastSwitch firmware resides. | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.87.1.1.1 |
| c2900InfoBoardIdentifier Returns the identifier of the main board
on which the FastSwitch firmware resides. | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.87.1.1.10 |
| c2900InfoPeakBuffersUsed The maximum number of 64-byte buffers used in the
main switch buffer pool. | scalar | buffers SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.87.1.1.2 |
| c2900InfoAddrCapacity The system-wide maximum number of MAC addresses
supported in the address table, a primary
resource when forwarding frames through a bridge.
The address table is dynamically update… | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.87.1.1.4 |
| c2900InfoRestrictedStaticAddrCapacity The system-wide maximum number of static addresses
supported. A static address is one that has explicit
source port filtering information assigned.
This number limits … | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.87.1.1.5 |
| c2900InfoSelfTestFailed A bit array where the presence of a particular bit
indicates a failure of a specific Power On Self Test.
Bit 0 - System Board Failure
Bit 1 - CPU Buffer Failure
Bit 2 - Notify RAM… | scalar | OctetString | .1.3.6.1.4.1.9.9.87.1.1.6 |
| c2900InfoUtilDisplay The number of utilization meter LEDs currently
lit on the front panel, if the value of
c2900InfoVisualIndicatorMode is selected as
utilization(4). More LEDs are lit
as more total… | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.9.9.87.1.1.7 |
| c2900InfoVisualIndicatorMode This object reflects what is currently selected
as the visual indication mode, selected by the
mode button.
The portStatus(1) mode uses the visual LEDS
to indicate port… | scalar | Enumeration | .1.3.6.1.4.1.9.9.87.1.1.8 |
| c2900InfoRedunantPowerSupplyInfo The switch allows a redundant power supply in addition
to its local power supply. Only one power source can be
supplying power to a unit.
absent(1) :the redundant power… | scalar | Enumeration | .1.3.6.1.4.1.9.9.87.1.1.9 |