cienaCesInputPUEntityId
CIENA-CES-TIME-SYNC-MIB ·
.1.3.6.1.4.1.1271.2.1.28.1.1.6.1.1
Object
column
Integer32
The unique identifier of this input protection unit.
Context
- MIB
- CIENA-CES-TIME-SYNC-MIB
- OID
.1.3.6.1.4.1.1271.2.1.28.1.1.6.1.1- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- cienaCesSyncInputProtectionUnitEntry
- Table
- cienaCesSyncInputProtectionUnitTable
- Siblings
- 18
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-48
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cienaCesInputPUSsmEnabled Enable/disable reading of actual received clock quality level for
this input protection unit. | column | Enumeration | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.10 |
| cienaCesInputPUOperationalStatus Operational status of this input protection unit. | column | SyncRefOperationalStatus | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.11 |
| cienaCesInputPUBITSSignalMode BITS Signal Mode, set if BITS signal is used as a protection unit. | column | SyncBITSSignalMode | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12 |
| cienaCesInputPUBITSSignalFormat BITS Signal Format, set if BITS signal is used as a protection unit. | column | SyncBITSSignalFormat | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.13 |
| cienaCesInputPUBITSSignalEncoding BITS Signal encoding, set if BITS signal is used as a protection unit. | column | SyncBITSSignalEncoding | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.14 |
| cienaCesInputPUUserOverridePriority The user configured override-priority of this input protection unit. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.15 |
| cienaCesInputPUPTPEncapType PTP Encapsulation Type, set if a PTP input is used as a protection unit. | column | SyncPTPEncapType | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.16 |
| cienaCesInputPUGPSClockMode GPS clock mode, set if a GPS input is used as a protection unit. | column | SyncTimingType | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.17 |
| cienaCesInputPUGPSFreqClock GPS frequency clock, set if a GPS input is used as a protection unit and the
cienaCesInputPUGPSClockMode is set to frequency. | column | SyncGPSFreqClock | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.18 |
| cienaCesInputPUBITSSignalSsmLocation BITS Signal Ssm Location, set if BITS signal is used as an input reference. | column | Enumeration | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.19 |
| cienaCesInputPUEntityName The unique name of this input protection unit. | column | OctetString | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.2 |
| cienaCesInputPUPGEntityName The identifier of the input protection group(s) which this input
protection unit belongs to. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.3 |
| cienaCesInputPUTimingInterfaceName The interface name of this input protection unit. | column | OctetString | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.4 |
| cienaCesInputPUTimingInterfaceProtocol The interface protocol of this input protection unit. | column | SyncInterfaceProtocol | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.5 |
| cienaCesInputPUUserPriority The user configured priority of this input protection unit. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.6 |
| cienaCesInputPUOperationalQL Operational clock quality level of this input protection unit. | column | SsmStratumLevel | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.7 |
| cienaCesInputPUForcedQL User configured clock quality level that this input protection unit
is forced to operate at. | column | SsmStratumLevel | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.8 |
| cienaCesInputPUReceivedQL Actual received clock quality level of this input protection unit. | column | SsmStratumLevel | .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.9 |