cienaCesModuleProtectionModeColdNotification
CIENA-CES-MODULE-MIB ·
.1.3.6.1.4.1.1271.2.2.3.0.11
Object
notification
This notification is sent when the protection mode of the system changes to cold. A COLD protection level is the lowest level of protection. It implies that the secondary CTM is ready to assume the function of the primary CTM but a failure causing a failover would be service impacting. The secondary CTM has been synchronized with the same software package, configuration files, etc such that it will return the same state as the previous primary CTM. The protection state of the primary CTM shall not transition from NONE to PROTECTED until the secondary CTM has completed the synchronization. In the case of a failure on the primary CTM, the secondary CTM will immediately assume primary status, finish its initialization and reboot the PSLMs. The primary CTM will reapply the configuration to the PSLMs after they have booted. Any unsaved configuration changes will NOT be lost on a failover as configuration changes are propagated to the secondary CTM configuration. To enable the device to send this notification: - cienaCesModuleAllModulesTrapState needs to be set to enabled. - cienaCesModuleProtectionModeTrapState needs to be set to enabled. The above values are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, and cienaCesModuleSystemProtectionMode.
Context
- MIB
- CIENA-CES-MODULE-MIB
- OID
.1.3.6.1.4.1.1271.2.2.3.0.11- Type
- notification
- Status
- current
- Parent
- cienaCesModuleMIBNotifications
- Siblings
- 26
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cienaCesModuleStateChangeNotification A cienaCesModuleStateChange notification is sent when the operational
state of the module is changed.
To enable the device to send this notification:
- cienaCesModuleAllModulesTr… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.1 |
| cienaCesModuleHASwitchOverNotification This notification is sent for CTM switchover.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be set to enabled.
- cienaCesModuleHAT… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.10 |
| cienaCesModuleProtectionModeWarmNotification This notification is sent when the protection mode of the system changes to warm.
This state is not supported on the 5410 platform.
To enable the device to send this notification:… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.12 |
| cienaCesModuleProtectionModeUnprotectedNotification This notification is sent when the protection mode of the system changes to unprotected.
A protection level of unprotected implies that there is no secondary CTM present in the sy… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.13 |
| cienaCesModuleProtectionModeHotNotification This notification is sent when the protection mode of the system changes to hot.
A HOT protection level is the highest level of protection. It implies that the secondary CTM is r… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.14 |
| cienaCesModulePostErrorNotification This notification is sent when a module POST error is detected.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be set to enabled.
-… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.15 |
| cienaCesModuleFastReloadUnsuccessfulNotification This notification is sent when the deprov (cold switchover or failover) fails.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be set… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.16 |
| cienaCesModuleHitlessModeUnsuccessfulNotification This notification is sent when the audit (hot failover or switchover) fails.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be set t… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.17 |
| cienaCesModuleSwitchFabricDisruptedUnrecoverableNotification This notification is sent when the switch fabric detects a game-over failure and the system
cannot automatically correct without resetting certain fabric subsystems. This kind of … | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.18 |
| cienaCesModuleSwitchFabricDisruptedRecoverableNotification This notification is sent when the switch fabric detects game-over failure and the system
can automatically correct it.
To enable the device to send this notification:
- cie… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.19 |
| cienaCesModuleHealthStatusUnknownNotification This notification is sent whenever the Health Manager detects a status change to unknown.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState need… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.2 |
| cienaCesModuleBladeInsertedNotification This notification is sent when a line module is inserted.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be set to enabled.
- cienaCe… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.20 |
| cienaCesModuleBladeRemovedNotification This notification is sent when a line module is removed.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be set to enabled.
- cienaCes… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.21 |
| cienaCesModuleSwitchFabricDisruptedRecoverableClrNotification This notification is sent when the game-over failure is automatically corrected.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.22 |
| cienaCesModuleConfigEntryCreatedNotification This notification is sent when a line module configuration entry is created.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be set to… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.23 |
| cienaCesModuleConfigEntryDeletedNotification This notification is sent when a line module configuration entry is deleted.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs to be set to… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.24 |
| cienaCesClockRateMismatchNotification This notification is sent when it is discovered that clock rate is not same on all cards.
This kind of error may affect traffic on the whole system and is a critical interruption.… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.25 |
| cienaCesModuleIncompatibilityNotification This notification is sent when it is discovered that module model is not compatible with current
datapath mode. Such condition indicates that such configuration is not supported, … | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.26 |
| cienaCesModuleLatchOpenNotification This notification is sent when the ejector latch(es) on a module have been released,
likely in preparation for module removal.
To enable the device to send this notification:
- … | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.27 |
| cienaCesModuleHealthStatusWarningNotification This notification is sent whenever the Health Manager detects a status change to warning.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState need… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.3 |
| cienaCesModuleHealthStatusFaultedNotification This notification is sent whenever the Health Manager detects a status change to faulted.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState need… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.4 |
| cienaCesModuleHealthStatusDegradedNotification This notification is sent whenever the Health Manager detects a status change to degraded.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState nee… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.5 |
| cienaCesModuleHealthStatusGoodNotification This notification is sent whenever the Health Manager detects a status change to normal.
To enable the device to send this notification:
- cienaCesModuleAllModulesTrapState needs… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.6 |
| cienaCesModuleSensorHighTempNotification This notification is sent when the cienaCesModuleSensor temperature exceeds the high
temperature threshold for the module.
To enable the device to send this notification:
- cienaC… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.7 |
| cienaCesModuleSensorLowTempNotification This notification is sent when the cienaCesModuleSensor falls below the low
temperature threshold for the module.
To enable the device to send this notification:
- cienaCesModuleA… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.8 |
| cienaCesModuleSensorNormalTempNotification This notification is sent if the cienaCesModule temperature changes
from previously reported high or low temperature exceeding thresholds to normal temperature.
To enable the devi… | notification | - | .1.3.6.1.4.1.1271.2.2.3.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| CIENA-GLOBAL-MIBcienaGlobalSeverity This object defines the severity of a trap and is a part of every trap defined in the system. | scalar | CIENA-TCCienaGlobalSeverity | .1.3.6.1.4.1.1271.1.3.1 |
| CIENA-GLOBAL-MIBcienaGlobalMacAddress This object indicates the chassis MAC address. | scalar | SNMPv2-TCMacAddress | .1.3.6.1.4.1.1271.1.3.2 |
| cienaCesModuleSystemProtectionMode This object indicates the protection mode of the system. | scalar | Enumeration | .1.3.6.1.4.1.1271.2.1.2.1.3.1 |