cienaCesModuleLastRebootReason
CIENA-CES-MODULE-MIB ·
.1.3.6.1.4.1.1271.2.1.2.1.2.1.1.11
Object
column
Enumeration
This object indicates the last reboot reason of the module.
Context
- MIB
- CIENA-CES-MODULE-MIB
- OID
.1.3.6.1.4.1.1271.2.1.2.1.2.1.1.11- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cienaCesModuleEntry
- Table
- cienaCesModuleTable
- Siblings
- 18
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | unknown |
2 | snmp |
3 | pwrFail |
4 | appLoad |
5 | errorHandler |
6 | watchdog |
7 | upgrade |
8 | cli |
9 | resetButton |
10 | failOver |
11 | faultManager |
12 | communicationFailure |
13 | configurationRevert |
14 | unprotectedFailure |
15 | bootFailure |
16 | softwareRevert |
17 | processorWarmRestart |
18 | coldRestart |
19 | primaryRestart |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cienaCesModuleChassisIndx This object indicates the chassis index for the module. | column | Unsigned32 | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.1 |
| cienaCesModuleStandbyStatus This object indicates the standby status of the module. | column | Enumeration | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.10 |
| cienaCesModuleAdminPostState This object sets the POST administrative state for the given module. | column | CIENA-TCCienaGlobalState | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.12 |
| cienaCesModuleOperPostState This object indicates the POST operational state for the given module. | column | CIENA-TCCienaGlobalState | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.13 |
| cienaCesModuleTrapState This object indicates whether the device generates notifications for this module. | column | CIENA-TCCienaGlobalState | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.16 |
| cienaCesModuleChassisNotifIndx This object indicates the chassis index for the module used in trap definition. | column | Unsigned32 | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.17 |
| cienaCesModuleShelfNotifIndx This object indicates the shelf index for the module used in trap definition. | column | Unsigned32 | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.18 |
| cienaCesModuleSlotNotifIndx This object indicates the slot index for the module used in trap definition. | column | Unsigned32 | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.19 |
| cienaCesModuleShelfIndx This object indicates the shelf index for the module. | column | Unsigned32 | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.2 |
| cienaCesModuleSlotName This object indicates the slot name that the module is installed in. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.20 |
| cienaCesModuleLatchLocation This object indicates the location of the module ejector latch. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.21 |
| cienaCesModuleSlotIndx This object indicates the slot index for the module. | column | Unsigned32 | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.3 |
| cienaCesModuleModel This object indicates the module model. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.4 |
| cienaCesModuleType This object indicates whether this is a single module, control timing module,
I/O module or fabric module. | column | Enumeration | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.5 |
| cienaCesModuleDescription This object indicates the description of the module. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.6 |
| cienaCesModuleAdminState This object indicates the administrative state of the module. | column | Enumeration | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.7 |
| cienaCesModuleOperState This object indicates the operational state of the module. | column | Enumeration | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.8 |
| cienaCesModuleProtectionRole This object indicates the redundant administrative state of the module. | column | Enumeration | .1.3.6.1.4.1.1271.2.1.2.1.2.1.1.9 |