cienaCesCfmGlobalSLMDefaultInterval
CIENA-CES-CFM-MIB ·
.1.3.6.1.4.1.1271.2.1.4.1.11.6
Object
scalar
SNMPv2-SMIInteger32
The global default interval for synthetic loss measurement tests.
The value ranges from 3 to 7.
The values 3-7 represent indices to CFM intervals as follows:
3 --> 100ms,
4 --> 1sec,
5 --> 10sec,
6 --> 1min,
7 --> 10min.
Context
- MIB
- CIENA-CES-CFM-MIB
- OID
.1.3.6.1.4.1.1271.2.1.4.1.11.6- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- cienaCesCfmGlobal
- Siblings
- 6
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cienaCesCfmState This object indicates the globally configured CFM state. | scalar | CIENA-TCCienaGlobalState | .1.3.6.1.4.1.1271.2.1.4.1.11.1 |
| cienaCesCfmEtherType This object indicates the Ethertype value used for CFM frames. | scalar | EthType | .1.3.6.1.4.1.1271.2.1.4.1.11.2 |
| cienaCesCfmMEPHoldTime This object indicates the time to hold a MEP in an inactive state. | scalar | milliseconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.4.1.11.3 |
| cienaCesCfmY1731EtherType This object indicates the optional alternate Ethertype for Y.1731 frames. | scalar | EthType | .1.3.6.1.4.1.1271.2.1.4.1.11.4 |
| cienaCesCfmGlobalSLMDefaultCount The global default count for synthetic loss measurement tests. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.4.1.11.5 |
| cienaCesCfmGlobalSLMDefaultTimeout The global default timeout for synthetic loss measurement tests. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1271.2.1.4.1.11.7 |