cie1000PortStatusVeriPhyResultIfIndex
CIE1000-PORT-MIB ·
.1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.1
Object
column
CIE1000-TCCIE1000InterfaceIndex
Logical interface number.
Context
- MIB
- CIE1000-PORT-MIB
- OID
.1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.1- Type
- column
- Access
- notifyonly
- Status
- current
- Parent
- cie1000PortStatusVeriPhyResultEntry
- Table
- cie1000PortStatusVeriPhyResultTable
- Siblings
- 8
Syntax
CIE1000-TCCIE1000InterfaceIndex
- Source
- CIE1000-TCCIE1000InterfaceIndex
- Base type
Integer32
Values & Constraints
Type Constraints
range: 0..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cie1000PortStatusVeriPhyResultVeriPhyStatusPairA VeriPhy status for the cable pair
0 - Cable is Correctly terminated pair
1 - Open pair
2 - Shorted pair
4 - Abnormal te… | column | CIE1000PortPhyVeriPhyStatus | .1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.2 |
| cie1000PortStatusVeriPhyResultVeriPhyStatusPairB VeriPhy status for the cable pair
0 - Cable is Correctly terminated pair
1 - Open pair
2 - Shorted pair
4 - Abnormal te… | column | CIE1000PortPhyVeriPhyStatus | .1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.3 |
| cie1000PortStatusVeriPhyResultVeriPhyStatusPairC VeriPhy status for the cable pair
0 - Cable is Correctly terminated pair
1 - Open pair
2 - Shorted pair
4 - Abnormal te… | column | CIE1000PortPhyVeriPhyStatus | .1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.4 |
| cie1000PortStatusVeriPhyResultVeriPhyStatusPairD VeriPhy status for the cable pair
0 - Cable is Correctly terminated pair
1 - Open pair
2 - Shorted pair
4 - Abnormal te… | column | CIE1000PortPhyVeriPhyStatus | .1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.5 |
| cie1000PortStatusVeriPhyResultVeriPhyLengthStatusPairA VeriPhy status cable length i meters for the cable pair. When VeriPhy
is completed, the cable diagnostics results is shown in the VeriPhy
status table. Note that VeriPHY is only a… | column | CIE1000-TCCIE1000Unsigned8 | .1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.6 |
| cie1000PortStatusVeriPhyResultVeriPhyLengthStatusPairB VeriPhy status cable length i meters for the cable pair. When VeriPhy
is completed, the cable diagnostics results is shown in the VeriPhy
status table. Note that VeriPHY is only a… | column | CIE1000-TCCIE1000Unsigned8 | .1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.7 |
| cie1000PortStatusVeriPhyResultVeriPhyLengthStatusPairC VeriPhy status cable length i meters for the cable pair. When VeriPhy
is completed, the cable diagnostics results is shown in the VeriPhy
status table. Note that VeriPHY is only a… | column | CIE1000-TCCIE1000Unsigned8 | .1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.8 |
| cie1000PortStatusVeriPhyResultVeriPhyLengthStatusPairD VeriPhy status cable length i meters for the cable pair. When VeriPhy
is completed, the cable diagnostics results is shown in the VeriPhy
status table. Note that VeriPHY is only a… | column | CIE1000-TCCIE1000Unsigned8 | .1.3.6.1.4.1.9.9.832.1.11.1.3.3.1.1.9 |