cMsDwdmIfTransportReferencePower
CERENT-MSDWDM-MIB ·
.1.3.6.1.4.1.3607.2.40.1.2.1.4
Object
column
OpticalPowerInDbm
This object is used to specify the optical transport reference power. This is the value of power the network element will expect on the photodiode. In case the user wants to refine this value the 'cMsDwdmIfTransportCalibratedPower' can be used to add an offset to the network element setup value.
Context
- MIB
- CERENT-MSDWDM-MIB
- OID
.1.3.6.1.4.1.3607.2.40.1.2.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cMsDwdmIfTransportEntry
- Table
- cMsDwdmIfTransportTable
- Siblings
- 17
Syntax
OpticalPowerInDbm
- Source
- OpticalPowerInDbm
- Base type
Integer32
Values & Constraints
Type Constraints
range: -1000
range: -400..250
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cMsDwdmIfTransportRingDirection obsolete This object is used to specify the ring directionality of
the port.
The ring directionality gives the configuration of the
facing side: facing sides can be east go… | column | RingDirection | .1.3.6.1.4.1.3607.2.40.1.2.1.1 |
| cMsDwdmIfTransportReferenceTilt This object is used to specify the amplifier tilt value
calculated by the network element. | column | OpticalAttenInDb | .1.3.6.1.4.1.3607.2.40.1.2.1.10 |
| cMsDwdmIfTransportCalibratedTilt This object is used to specify the amplifier tilt offset
added as offset by user in order to tune the network element
calculated ('reference') value | column | OpticalAttenInDb | .1.3.6.1.4.1.3607.2.40.1.2.1.11 |
| cMsDwdmIfTransportDCULoss This object is used to specify the value of Insertion
Loss measured for the Dispersion Compensation Unit | column | OpticalAttenInDb | .1.3.6.1.4.1.3607.2.40.1.2.1.12 |
| cMsDwdmIfTransportOSRI This value indicates the status of the Optical Safety Remote Interlock
Valid values are -
enable(1) : the OSRI is enable
disable(2) : the OSRI is disable
none(3) … | column | Enumeration | .1.3.6.1.4.1.3607.2.40.1.2.1.13 |
| cMsDwdmIfTransportExpectedGain This object is used to specify the value of the expected gain
of an amplifier | column | OpticalAttenInDb | .1.3.6.1.4.1.3607.2.40.1.2.1.14 |
| cMsDwdmIfTransportSideIdentifier This object is used to specify the facing side of the optical
port. | column | SideIdentifier | .1.3.6.1.4.1.3607.2.40.1.2.1.15 |
| cMsDwdmIfTransportAddPower This object is used to specify the ADD optical power read at
the photodiode of the port.
The distinguished value of '-1000' indicates that the power
cannot be read … | column | OpticalPowerInDbm | .1.3.6.1.4.1.3607.2.40.1.2.1.16 |
| cMsDwdmIfTransportOSCPower This object is used to specify the OSC optical power read at
the photodiode of the port.
The distinguished value of '-1000' indicates that the power
cannot be read … | column | OpticalPowerInDbm | .1.3.6.1.4.1.3607.2.40.1.2.1.17 |
| cMsDwdmIfTransportTDCUCompensation This object is used to specify the TDCU Compensation value
of the optical port belong to a TDCU card. | column | TDCUCompensation | .1.3.6.1.4.1.3607.2.40.1.2.1.18 |
| cMsDwdmIfTransportPortRule This object is used to specify the type of the optical
port.
A transport optical port can assume one of the following
values:
input(1)
input-express(2)
output(3)… | column | OpticalPortRule | .1.3.6.1.4.1.3607.2.40.1.2.1.2 |
| cMsDwdmIfTransportPower This object is used to specify the optical power read at
the photodiode of the port.
The distinguished value of '-1000' indicates that the power
cannot be read due … | column | OpticalPowerInDbm | .1.3.6.1.4.1.3607.2.40.1.2.1.3 |
| cMsDwdmIfTransportCalibratedPower This object is used to specify the optical transport
calibration power. This is the power offset that user
contribute in case the 'reference' value setup by
network element woul… | column | OpticalPowerInDbm | .1.3.6.1.4.1.3607.2.40.1.2.1.5 |
| cMsDwdmIfTransportInsertionLoss This object is used to specify the value of Insertion
Loss of the optical port. | column | OpticalAttenInDb | .1.3.6.1.4.1.3607.2.40.1.2.1.6 |
| cMsDwdmIfTransportLaserStatus This object is used to specify the status of the laser. | column | LaserStatus | .1.3.6.1.4.1.3607.2.40.1.2.1.7 |
| cMsDwdmIfTransportAmplifierMode This object is used to specify the working amplifier
mode. | column | OpticalAmplifierMode | .1.3.6.1.4.1.3607.2.40.1.2.1.8 |
| cMsDwdmIfTransportGain This object is used to specify the value of the gain
of an amplifier | column | OpticalAttenInDb | .1.3.6.1.4.1.3607.2.40.1.2.1.9 |