configLogin
CENTILLION-CONFIG-MIB ·
.1.3.6.1.4.1.930.2.1.2.13
Object
scalar
mandatory
r/w
OctetString
The system login object. This object is used to login
a network management station to the system for configuration.
The format of the login request follows:
login indicator.login password,
where the login indicator is a single byte of the value
1 = logoff, 2 = login, or 3 = set password and the password
is the system password. The password must be supplied for
upon login or altering the password. A manager must first
login to the system before altering the password.
When read, the first octet is returned, indicating whether
a managment station is currently logged in to the system.
Context
- MIB
- CENTILLION-CONFIG-MIB
- OID
.1.3.6.1.4.1.930.2.1.2.13- Type
- scalar
- Access
- readwrite
- Status
- mandatory
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.