cadDQoSGateTimerT8
CADANT-DQOS-GATE-MIB ·
.1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.21
Object
column
r/w
seconds Unsigned32
The CMTS MUST set the Timeout for Active QoS Parameters for the service
flow to the value specified by this timer. The Timeout for Active QoS
Parameters limits the period of time resources remain unused on an
active service flow. See Appendix C,
section C.2.2.5.6 of the DOCSIS RFI for more details on the use of
this timer.
In order to allow the EMTA to refresh this timer, the CMTS MUST inform
the EMTA of the Timeout for Active QoS Parameters value in the
response (i.e. in the DSA-RSP) to the EMTA's reservation request.
The default value of this timer is 0, which instructs the CMTS not to
poll for activity on the service flow.
Context
- MIB
- CADANT-DQOS-GATE-MIB
- OID
.1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.21- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- cadDQoSGateEntry
Syntax
seconds Unsigned32
Values & Constraints
Object Constraints
range: 0-60000