column r/w seconds Unsigned32
The CMTS MUST set the Timeout for Active QoS Parameters for the service
flow to the value specified by this timer.  The Timeout for Active QoS
Parameters limits the period of time resources remain unused on an
active service flow.  See Appendix C,
section C.2.2.5.6 of the DOCSIS RFI for more details on the use of 
this timer.
              
In order to allow the EMTA to refresh this timer, the CMTS MUST inform
the EMTA of the Timeout for Active QoS Parameters value in the 
response (i.e. in the DSA-RSP) to the EMTA's reservation request.
              
The default value of this timer is 0, which instructs the CMTS not to
poll for activity on the service flow.

Context

MIB
CADANT-DQOS-GATE-MIB
OID
.1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.21
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
cadDQoSGateEntry
Table
cadDQoSGateTable
Siblings
39

Syntax

seconds Unsigned32

Values & Constraints

Object Constraints
range: 0-60000