cadDQoSGateTimerT7
CADANT-DQOS-GATE-MIB ·
.1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.20
Object
column
r/w
seconds Unsigned32
The CMTS MUST set the Timeout for Admitted QoS Parameters for the
service flow to the value specified by this timer. The timeout for
Admitted QoS Parameters limits the period of time that the CMTS must
hold resources for a service flow's Admitted QoS Parameter Set while
they are in excess of its Active QoS Parameter Set. See Appendix C,
section C.2.2.5.7 of the DOCSIS RFI for more details on the use of
this timer.
In order to allow the EMTA to refresh this timer, the CMTS MUST inform
the EMTA of the Timeout for Admitted QoS Parameters value in the
response (i.e. in the DSA-RSP) to the EMTA's reservation request.
The recommended default value of this timer is 200 seconds.
Context
- MIB
- CADANT-DQOS-GATE-MIB
- OID
.1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.20- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- cadDQoSGateEntry
Syntax
seconds Unsigned32
Values & Constraints
Object Constraints
range: 0-60000