rip2AuthFailTrap
CADANT-CMTS-NOTIFICATION-MIB ·
.1.3.6.1.4.1.4998.1.1.6.1.1.0.6
Object
notification
An event to report rip2 authentication failed.
Context
- MIB
- CADANT-CMTS-NOTIFICATION-MIB
- OID
.1.3.6.1.4.1.4998.1.1.6.1.1.0.6- Type
- notification
- Status
- current
- Parent
- cadTraps
- Siblings
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| aaaServerUnreachableTrap An event to report that the AAA (RADIUS or TACACS+) server is not responding | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.1 |
| cadLinkUp This is to expand standard linkUp trap to include ifDescr.
A linkUp trap signifies that the SNMP entity, acting in an
agent role, has detected that the ifOperStatus object for
one… | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.10 |
| aaaServerGroupUnreachableTrap An event to report that all the hosts in the AAA (RADIUS or TACACS+) server
group are not responding | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.2 |
| aaaServerAuthFailTrap An event to report that AAA (RADIUS or TACACS+) server rejected the authentication request | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.3 |
| secuLocalAuthFailTrap An event to report that local password authentication failed | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.4 |
| secuLineAuthFailTrap An event to report that line password authentication failed | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.5 |
| cadIpdrNoPrimaryCollector An event to report IPDR Streaming is enabled but there is no primary collector connected. | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.7 |
| cadIpdrStreamingDisabled An event to report IPDR Streaming function has been turned off. | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.8 |
| cadIpdrReportCycleMissed An event to report CMTS was not able to start the scheduled IPDR report cycle session on time.
This may be due to system or network load or the lack of primary collector connectio… | notification | - | .1.3.6.1.4.1.4998.1.1.6.1.1.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| CADANT-CMTS-EQUIPMENT-MIBtrapCounter This is the trap sequence number that increments each
time a trap is sent. It is persistent across resets. | scalar | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4998.1.1.10.1.1.2 |
| CADANT-CMTS-EQUIPMENT-MIBtrapSeverity Severity level of a Cadant trap. | scalar | Enumeration | .1.3.6.1.4.1.4998.1.1.10.1.1.3 |
| securityInfo The detail security failure information | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4998.1.1.6.1.1.1.1 |