cadIfMacDomainDownChannelMaxFrequency
CADANT-CMTS-LAYER2CMTS-MIB ·
.1.3.6.1.4.1.4998.1.1.20.1.4.2.1.38
Object
column
r/w
hertz Integer32
This object is used to configure the C4 CMTS to accept maximum downstream frequency limit that conform with the EuroDOCSIS specifications (starndard range 112 MHz to 858 MHz), (extended 85 MHz to 999MHz) or to the DOCSIS specifications (standard 91 to 867 MHz), (extended range 57 MHz to 999 MHz). Changes to downstream frequency and width are verified against this object to ensure the C4 CMTS does not exceed the downstream spectrum limits imposed by this object. Attempting to decrease the downstream frequency spectrum implied by this object will fail if at least a single downstream is configured outside of the range for the new value. It is recommended this object be set during initial system setup.
Context
- MIB
- CADANT-CMTS-LAYER2CMTS-MIB
- OID
.1.3.6.1.4.1.4998.1.1.20.1.4.2.1.38- Type
- column
- Access
- readwrite
- Status
- current
- Units
- hertz
- Parent
- cadIfMacDomainEntry
Syntax
hertz Integer32
Values & Constraints
Object Constraints
range: 858000000-858000000
range: 867000000-867000000
range: 999000000-999000000