cadBpi2CmtsCheckCertValidityPeriods
CADANT-CMTS-BPI2-MIB ·
.1.3.6.1.4.1.4998.1.1.5.5.1.1.4
Object
Setting this object to TRUE causes all certificates obtained thereafter to have their validity periods (and their chain's validity periods) checked against the current time of day. A FALSE setting will cause all certificates obtained thereafter to not have their validity periods (nor their chain's validity periods) checked against the current time of day.
Context
- MIB
- CADANT-CMTS-BPI2-MIB
- OID
.1.3.6.1.4.1.4998.1.1.5.5.1.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cadBpi2CmtsBaseEntry
- Table
- cadBpi2CmtsBaseTable
- Siblings
- 3
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cadBpi2CmtsDefaultAuthLifetime The value of this object is the default lifetime, in
seconds, the CMTS assigns to a new authorization key. | column | seconds Integer32 | .1.3.6.1.4.1.4998.1.1.5.5.1.1.1 |
| cadBpi2CmtsDefaultTEKLifetime The value of this object is the default lifetime, in
seconds, the CMTS assigns to a new Traffic Encryption Key
(TEK). | column | seconds Integer32 | .1.3.6.1.4.1.4998.1.1.5.5.1.1.2 |
| cadBpi2CmtsDefaultSelfSignedManufCertTrust This object determines the default trust of all (new)
self-signed manufacturer certificates obtained after setting