sBTAModulesRPCSourceSwitchCount
Baytech-MIB-403-1 ·
.1.3.6.1.4.1.4779.1.3.5.2.1.22
Object
column
mandatory
Integer32
Count of Voltage Source Switches for this RPC.
Context
- MIB
- Baytech-MIB-403-1
- OID
.1.3.6.1.4.1.4779.1.3.5.2.1.22- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- sBTAModulesRPCEntry
- Table
- sBTAModulesRPCTable
- Siblings
- 23
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sBTAModulesRPCIndex mandatory The index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula:
((module - 2) * 4) + port. For example module 3 port 1 = index … | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.1 |
| sBTAModulesRPCAllOutletsCmd mandatory Turns all outlets on, off or reboot.
0 = off
1 = on
2 = reboot
A get will return unknown (6). | column | Enumeration | .1.3.6.1.4.1.4779.1.3.5.2.1.10 |
| sBTAModulesRPCAllOutletsStatus mandatory Reports status of outlets in a comma deliminated string.
0 = off
1 = on
2 = reboot
3 = locked on
4 = locked off | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.2.1.11 |
| sBTAModulesRPCCurrentAlarmThreshold mandatory The current alarm threshold level *10. A value of 105 will set the level to 10.5. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.12 |
| sBTAModulesRPCOverVoltageThreshold mandatory The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.13 |
| sBTAModulesRPCUnderVoltageThreshold mandatory The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.14 |
| sBTAModulesRPCNumberOfOutlets mandatory Number of outlets for this RPC.
This will be the size of outlet table for this RPC index. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.15 |
| sBTAModulesRPCCircuitBreaker mandatory Status of circuit breaker in power strip. 0=off 1=on. | column | Enumeration | .1.3.6.1.4.1.4779.1.3.5.2.1.16 |
| sBTAModulesRPCOverTempThreshold mandatory The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.17 |
| sBTAModulesRPCUnitVA mandatory Total Volt-Amps for this RPC. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.18 |
| sBTAModulesRPCNumberOfBreakers mandatory Number of breakers for this RPC. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.19 |
| sBTAModulesRPCName mandatory The name (unit id) of the rpc. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.2.1.2 |
| sBTAModulesRPCLowCurrentThreshold mandatory Low current threshold for this RPC. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.20 |
| sBTAModulesRPCVoltageSource mandatory Voltage source for this RPC. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.21 |
| sBTAModulesRPCNumberOfSensors mandatory Number of environmental sensors for this RPC. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.23 |
| sBTAModulesRPCType mandatory The type of RPC installed at the indexed location. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.2.1.24 |
| sBTAModulesRPCFirmwareVersion mandatory The firware version of the rpc. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.2.1.3 |
| sBTAModulesRPCCurrent mandatory The current reading for the power strip.
If current measurement is not installed this value will always read 0. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.4 |
| sBTAModulesRPCMaxCurrent mandatory The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0.
Setting this value to 0 will clear the maximum cur… | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.5 |
| sBTAModulesRPCVoltage mandatory The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.6 |
| sBTAModulesRPCPower mandatory The power reading for the power strip.
If power measurement is not installed this value will always read 0. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.7 |
| sBTAModulesRPCTemperature mandatory The temperature reading for the power strip. Readings are in degrees C.
If temperature measurement is not installed this value will always read 0. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.8 |
| sBTAModulesRPCRebootTimeout mandatory The length of off time for automatic reboot sequences.
Currently a read-only value set to the fixed reboot timeout. | column | Integer32 | .1.3.6.1.4.1.4779.1.3.5.2.1.9 |