bwstraps
Barracuda-BWS ·
.1.3.6.1.4.1.20632.8.1
Object
node
No description available.
Context
- MIB
- Barracuda-BWS
- OID
.1.3.6.1.4.1.20632.8.1- Type
- node
- Parent
- bws
- Siblings
- 25
- Children
- 18
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| systemFanSpeed System Fan Speen in RPM. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.10 |
| cpuTemperature Cpu Temperature in degree Celsius. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.11 |
| firmwareStorage Firware Storage in percentage. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.12 |
| logStorage Log Storage in percentage. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.13 |
| highAvailabilityStatus High Availability Status. | scalar | OctetString | .1.3.6.1.4.1.20632.8.14 |
| operationalMode Operation Mode. | scalar | OctetString | .1.3.6.1.4.1.20632.8.15 |
| dataPathStatus Data Path Status. | scalar | OctetString | .1.3.6.1.4.1.20632.8.16 |
| linkStatus Link Status. | scalar | OctetString | .1.3.6.1.4.1.20632.8.17 |
| vipStatus VIP Status. | scalar | OctetString | .1.3.6.1.4.1.20632.8.18 |
| memUtilization Memory Utilization. | scalar | OctetString | .1.3.6.1.4.1.20632.8.19 |
| totalApplications Total applications configured. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.2 |
| cpuUtilization CPU Utilization . | scalar | OctetString | .1.3.6.1.4.1.20632.8.20 |
| totalBandwidth Total Bandwidth . | scalar | OctetString | .1.3.6.1.4.1.20632.8.21 |
| uptime Uptime. | scalar | OctetString | .1.3.6.1.4.1.20632.8.22 |
| totalMem Total Memory. | scalar | OctetString | .1.3.6.1.4.1.20632.8.23 |
| freeMem Free Memory. | scalar | OctetString | .1.3.6.1.4.1.20632.8.24 |
| totalServers Total servers configured. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.3 |
| totalAttacks Count of attacks in last one hour | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.4 |
| activeApplications Total Applications configured whose status is on | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.5 |
| bwsStats | node | - | .1.3.6.1.4.1.20632.8.50 |
| bwsMIBConformance | node | - | .1.3.6.1.4.1.20632.8.51 |
| activeServers Total Servers whose operational status is in-service | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.6 |
| bwsMessage System Log Message. | scalar | OctetString | .1.3.6.1.4.1.20632.8.7 |
| systemLoad System Load in percentage. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.8 |
| cpuFanSpeed Cpu Fan Speen in RPM. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20632.8.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| peerDown Severity: Error
Peer is down. | notification | - | .1.3.6.1.4.1.20632.8.1.10 |
| dataPortLinkUp Severity: Information
Peer is up. | notification | - | .1.3.6.1.4.1.20632.8.1.11 |
| serverUp Severity: Information
Back-end Server is up. | notification | - | .1.3.6.1.4.1.20632.8.1.12 |
| peerUp Severity: Information
Peer is up. | notification | - | .1.3.6.1.4.1.20632.8.1.13 |
| switchingToBypassMode Severity: Information
Switching to bypass mode. | notification | - | .1.3.6.1.4.1.20632.8.1.14 |
| switchingToInlineMode Severity: Information
Switching to inline mode. | notification | - | .1.3.6.1.4.1.20632.8.1.15 |
| sharedSecretKeyAboutToExpire Severity: Information
Shared secret key about to expire. | notification | - | .1.3.6.1.4.1.20632.8.1.16 |
| sharedSecretKeyExpired Severity: Information
Shared secret key expired. | notification | - | .1.3.6.1.4.1.20632.8.1.17 |
| firmwareStorageHigh Severity: Alert
Firmware storage exceeds 75%. | notification | - | .1.3.6.1.4.1.20632.8.1.18 |
| logStorageHigh Severity: Alert
Log storage exceeds 85%. | notification | - | .1.3.6.1.4.1.20632.8.1.19 |
| raidDegrading Severity: Alert
One of the RAID arrays is degrading. | notification | - | .1.3.6.1.4.1.20632.8.1.20 |
| tempCritical Severity: Alert
System temperature exceeded its threshold. | notification | - | .1.3.6.1.4.1.20632.8.1.3 |
| tempHigh Severity: Critical
System temperature is higher than 80C. | notification | - | .1.3.6.1.4.1.20632.8.1.4 |
| systemFailOver Severity: Critical
System has failed over. | notification | - | .1.3.6.1.4.1.20632.8.1.5 |
| switchingToMaintMode Severity: Warning
System is in failed state. | notification | - | .1.3.6.1.4.1.20632.8.1.6 |
| fanDead Severity: Error
One of the System fans is dead. | notification | - | .1.3.6.1.4.1.20632.8.1.7 |
| dataPortLinkDown Severity: Error
Data link is down. | notification | - | .1.3.6.1.4.1.20632.8.1.8 |
| serverDown Severity: Error
Back-end Server is down. | notification | - | .1.3.6.1.4.1.20632.8.1.9 |