eqptConnRowStatus
BTI-OL-MIB ·
.1.3.6.1.4.1.18070.2.2.1.16.5.1.100
Object
column
SNMPv2-TCRowStatus
The equipment connection table RowStatus object is not readable or writeable because all entries in the table are automatically created and deleted as equipment modules are assigned and unassigned to optical layer groupings. This equipment connection row status object is used only in database change notifications to indicate if the row has been created or deleted.
Context
- MIB
- BTI-OL-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.16.5.1.100- Type
- column
- Access
- notifyonly
- Status
- current
- Parent
- eqptConnEntry
- Table
- eqptConnTable
- Siblings
- 11
Values & Constraints
Type Values
1 | active |
2 | notInService |
3 | notReady |
4 | createAndGo |
5 | createAndWait |
6 | destroy |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eqptConnSrcCpTypeIdx The type of circuit pack on which the source port
of the equipment connection is located. | column | BTI-TC-MIBCpType | .1.3.6.1.4.1.18070.2.2.1.16.5.1.1 |
| eqptConnDstIdx The number of the port of the specified port type
of the destination port of the equipment connection. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.16.5.1.10 |
| eqptConnType The type of optical fiber patch cable for the equipment
connection entry. | column | Enumeration | .1.3.6.1.4.1.18070.2.2.1.16.5.1.11 |
| eqptConnSrcShelfIdx The number of the shelf on which the source port
of the equipment connection is located. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.16.5.1.2 |
| eqptConnSrcSlotIdx The number of the slot on which the source port
of the equipment connection is located. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.16.5.1.3 |
| eqptConnSrcPortTypeIdx The type of the source port of the equipment connection,
according to the function it provides. | column | OlPortType | .1.3.6.1.4.1.18070.2.2.1.16.5.1.4 |
| eqptConnSrcIdx The number of the port of the specified port type
of the source port of the equipment connection. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.16.5.1.5 |
| eqptConnDstCpTypeIdx The type of circuit pack on which the destination port
of the equipment connection is located. | column | BTI-TC-MIBCpType | .1.3.6.1.4.1.18070.2.2.1.16.5.1.6 |
| eqptConnDstShelfIdx The number of the shelf on which the destination port
of the equipment connection is located. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.16.5.1.7 |
| eqptConnDstSlotIdx The number of the slot on which the destination port
of the equipment connection is located. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.16.5.1.8 |
| eqptConnDstPortTypeIdx The type of the destination port of the equipment
connection, according to the function it provides. | column | OlPortType | .1.3.6.1.4.1.18070.2.2.1.16.5.1.9 |