xcvrProtSwOpCmd
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.11.9.2.1.5
Object
Used to perform a protection switch on a transceiver facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.11.9.2.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- xcvrProtSwOpEntry
- Table
- xcvrProtSwOpTable
- Siblings
- 4
Syntax
BTI-TC-MIBProtSwOpCmd
- Source
- BTI-TC-MIBProtSwOpCmd
- Base type
Enumeration
Values & Constraints
Object Constraints
range: 1-1
range: 11-11
range: 21-21
range: 31-31
Type Values
1 | noOp |
2 | manProtSw |
3 | frcdProtSw |
4 | lockout |
5 | release |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xcvrProtSwOpTypeIdx The specific type of wavelength conversion function of the
circuit pack of the transceiver port targeted for the
protection switching operation. | column | BTI-TC-MIBXcvrType | .1.3.6.1.4.1.18070.2.2.1.11.9.2.1.1 |
| xcvrProtSwOpShelfIdx The number of the shelf of the transceiver targeted for the
protection switching operation. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.9.2.1.2 |
| xcvrProtSwOpSlotIdx The number of the slot within which the transceiver targeted
for the protection switching operation is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.9.2.1.3 |
| xcvrProtSwOpIdx The number of the port on the circuit pack on which the
optical transceiver facility has been provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.9.2.1.4 |