vcnProtSwOpCmd
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1.6
Object
Used to perform a protection switch on a VC-N facility which is part of a protection group pairing, as described in the ProtSwOpCmd textual convention.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.11.15.1.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- vcnProtSwOpEntry
- Table
- vcnProtSwOpTable
- Siblings
- 5
Syntax
BTI-TC-MIBProtSwOpCmd
- Source
- BTI-TC-MIBProtSwOpCmd
- Base type
Enumeration
Values & Constraints
Type Values
1 | noOp |
2 | manProtSw |
3 | frcdProtSw |
4 | lockout |
5 | release |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vcnProtSwOpTypeIdx The specific type of VC-N signal targeted for the protection
switching operation. | column | BTI-TC-MIBVcnType | .1.3.6.1.4.1.18070.2.2.1.11.15.1.1.1 |
| vcnProtSwOpShelfIdx The number of the shelf of the VC-N facility targeted for the
protection switching operation. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.15.1.1.2 |
| vcnProtSwOpSlotIdx The number of the slot of the VC-N facility targeted for the
protection switching operation. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.15.1.1.3 |
| vcnProtSwOpPortIdx The number of the port of the VC-N facility targeted for the
protection switching operation. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.15.1.1.4 |
| vcnProtSwOpIdx The index number of the VC-N facility targeted for the
protection switching operation. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.15.1.1.5 |