stmnProtGrpEntry
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.10.3.1
Object
row
The conceptual row object of the STM-N facility protection group table.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.10.3.1- Type
- row
- Status
- current
- Parent
- stmnProtGrpTable
- Table
- stmnProtGrpTable
- Children
- 10
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| stmnProtGrpWorkTypeIdx The specific rate of the STM-N facility that serves as the
working facility for the protection group. Currently, only
STM-N facilities that are OTU-N mapped are supported for prot… | column | BTI-TC-MIBStmnType | .1.3.6.1.4.1.18070.2.2.1.10.3.1.1 |
| stmnProtGrpRowStatus Used to control the addition and deletion of entries in the
STM-N protection group table, which in turn controls
provisioning and deprovisioning of STM-N facility
protection group… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.18070.2.2.1.10.3.1.100 |
| stmnProtGrpWorkShelfIdx The number of the shelf of the STM-N facility that serves as
the working facility for the protection group. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.10.3.1.2 |
| stmnProtGrpWorkSlotIdx The number of the slot of the STM-N facility that serves as
the working facility for the protection group. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.10.3.1.3 |
| stmnProtGrpWorkPortIdx The number of the port of the STM-N facility that serves as
the working facility for the protection group. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.10.3.1.4 |
| stmnProtGrpProtTypeIdx The specific rate of the STM-N facility that serves as the
protection facility for the protection group. Currently, only
STM-N facilities that are OTU-N mapped are supported for p… | column | BTI-TC-MIBStmnType | .1.3.6.1.4.1.18070.2.2.1.10.3.1.5 |
| stmnProtGrpProtShelfIdx The number of the shelf of the STM-N facility that serves as
the protection facility for the protection group. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.10.3.1.6 |
| stmnProtGrpProtSlotIdx The number of the slot of the STM-N facility that serves as
the protection facility for the protection group. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.10.3.1.7 |
| stmnProtGrpProtPortIdx The number of the port of the STM-N facility that serves as
the protection facility for the protection group. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.10.3.1.8 |
| stmnProtGrpId Textual data recorded by the user to describe the provisioned
STM-N protection group in a manner useful to the user. | column | OctetString | .1.3.6.1.4.1.18070.2.2.1.10.3.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| dataCommsPingCpTypeIdx This object is used to indicate the type of circuit pack from
which the ping operation is to be conducted using the
dataCommsPingCmd object. | column | BTI-TC-MIBCpType | .1.3.6.1.4.1.18070.2.2.1.11.7.1.1.1 |
| dataCommsPingShelfIdx This object is used to indicate the shelf number containing
the circuit pack from which the ping operation is to be
conducted using the dataCommsPingCmd object. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.7.1.1.2 |
| dataCommsPingSlotIdx This object is used to indicate the slot number containing the
circuit pack from which the ping operation is to be conducted
using the dataCommsPingCmd object. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.7.1.1.3 |