oaOOBRSDOpTimer
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1.6
Object
column
r/w
Integer32
Used to specify the time duration of an override back reflection shutdown operation. It is only valid to set the value of this object in the same set request as for the oaOOBRSDOpCmd object. Despite the indicated value range, the actual supported range is 20 to 600. The value 0 is returned when this object is read, even if an overrideOBRSD operation is in progress.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.11.6.1.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- oaOOBRSDOpEntry
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.