dataCommsPingCpTypeIdx
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.1
Object
column
BTI-TC-MIBCpType
This object is used to indicate the type of circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.11.7.1.1.1- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- dataCommsPingEntry
- Table
- dataCommsPingTable
- Siblings
- 6
Syntax
BTI-TC-MIBCpType
- Source
- BTI-TC-MIBCpType
- Base type
Enumeration
Values & Constraints
Object Constraints
range: 1-4
Type Values
1 | scp |
2 | oba |
3 | ola |
4 | olam |
5 | opa |
6 | smf60 |
7 | smf80 |
12 | pmt1 |
13 | pmt2 |
14 | msi |
15 | esi |
16 | cu |
17 | fllr |
18 | smf40 |
20 | osc |
25 | c8md |
29 | c1adm |
32 | cdsc |
33 | d32md1 |
34 | d32md2 |
35 | d32md3 |
36 | d32md4 |
37 | d1adm |
38 | d2adm |
39 | d4adm |
41 | spa |
43 | oct |
44 | sba |
45 | smf30 |
46 | nf |
47 | wt |
48 | wr |
49 | cs |
50 | smf5 |
51 | smf10 |
52 | smf15 |
53 | smf20 |
54 | d32amd1 |
55 | d32amd2 |
56 | d32amd3 |
57 | d32amd4 |
58 | wm |
59 | c8md1 |
60 | c8md2 |
61 | mxp |
62 | c4md |
63 | c2adm |
64 | tpr |
65 | pvx |
66 | ccm |
67 | wc200 |
68 | dla |
69 | rob |
70 | dcm |
71 | d40md |
72 | d96md |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dataCommsPingShelfIdx This object is used to indicate the shelf number containing
the circuit pack from which the ping operation is to be
conducted using the dataCommsPingCmd object. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.7.1.1.2 |
| dataCommsPingSlotIdx This object is used to indicate the slot number containing the
circuit pack from which the ping operation is to be conducted
using the dataCommsPingCmd object. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.7.1.1.3 |
| dataCommsPingCmd This object is used to trigger a ping operation from an OSC or
SCP circuit pack. The description of DataCommsPingCmd textual
convention explains the usage of this object to perfor… | column | DataCommsPingCmd | .1.3.6.1.4.1.18070.2.2.1.11.7.1.1.4 |
| dataCommsPingAddress This object is used to indicate the IP Address which is the
target of the ping operation to be conducted using the
dataCommsPingCmd object. | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.18070.2.2.1.11.7.1.1.5 |
| dataCommsPingNumAttempts This object is used to indicate how many ping attempts are to
be made in the ping operation to be conducted using the
dataCommsPingCmd object. The default is 3. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.11.7.1.1.6 |
| dataCommsPingNumSuccesses This object is used to indicate how many ping trials attempted
in the ping operation resulted in a successful ping