briShelfIdx
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.4.16.1.1
Object
column
Integer32
The number of the shelf on which the BRI facility is provisioned.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.4.16.1.1- Type
- column
- Access
- notifyonly
- Status
- current
- Parent
- briEntry
- Table
- briTable
- Siblings
- 27
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| briOpticalPwrTransmitted The optical power transmitted at the output of the
transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.10 |
| briRowStatus Used to control the addition and deletion of entries in the
BRI table, which in turn controls provisioning and
deprovisioning of BRI facilities. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.18070.2.2.1.4.16.1.100 |
| briPEC An optionally provisioned Product Equipment Code used to
validate the physically present optical transceiver on the
BRI port. | column | OctetString | .1.3.6.1.4.1.18070.2.2.1.4.16.1.11 |
| briAdminStatus The administrative status of the BRI facility. | column | BTI-TC-MIBAdminStatus | .1.3.6.1.4.1.18070.2.2.1.4.16.1.12 |
| briOperStatus The reported operational status of the BRI facility. | column | BTI-TC-MIBOperStatus | .1.3.6.1.4.1.18070.2.2.1.4.16.1.13 |
| briOperStatQlfr This is a textual list of qualifiers about the reported
operational status of the BRI facility. | column | BTI-TC-MIBOperStatQlfr | .1.3.6.1.4.1.18070.2.2.1.4.16.1.14 |
| briAutoEnableTimer Specifies the auto-enable timer for the targeted BRI
facility. This value only applies if the briAdminStatus object
is set to autoEnabled. Otherwise, the value returned is
000-00. | column | BTI-TC-MIBHoursAndMinutes | .1.3.6.1.4.1.18070.2.2.1.4.16.1.15 |
| briActAutoEnableTimer Indicates the time remaining on the auto-enable timer if it is
actively counting down. Otherwise, the value returned is
000-00. | column | BTI-TC-MIBHoursAndMinutes | .1.3.6.1.4.1.18070.2.2.1.4.16.1.16 |
| briWavelength The wavelength to be transmitted by the transceiver on the
BRI facility port. This is a mandatory object when a
row of the fiber channel table is created. | column | BTI-TC-MIBFixedX100 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.17 |
| briVendorPN1 An optionally provisioned part number used to validate the
optical transceiver on the BRI facility port. | column | OctetString | .1.3.6.1.4.1.18070.2.2.1.4.16.1.18 |
| briVendorPN2 An optionally provisioned part number used to validate the
optical transceiver on the BRI facility port. | column | OctetString | .1.3.6.1.4.1.18070.2.2.1.4.16.1.19 |
| briSlotIdx The number of the slot within which the BRI facility
is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.2 |
| briVendorPN3 An optionally provisioned part number used to validate the
optical transceiver on the BRI facility port. | column | OctetString | .1.3.6.1.4.1.18070.2.2.1.4.16.1.20 |
| briPhyPMMon Indicates if the BRI facility is configured to
report threshold crossing conditions for physical layer
performance monitoring parameters. | column | Enumeration | .1.3.6.1.4.1.18070.2.2.1.4.16.1.21 |
| briLaserStatus An indication of the operational status of the transceiver
laser on the BRI facility port. | column | Enumeration | .1.3.6.1.4.1.18070.2.2.1.4.16.1.22 |
| briId1 Textual data recorded by the user to describe the provisioned
BRI facility in a manner useful to the user. | column | OctetString | .1.3.6.1.4.1.18070.2.2.1.4.16.1.23 |
| briFiberType An optional specification of the fiber type that interfaces to
the BRI facility port. | column | BTI-TC-MIBFiberType | .1.3.6.1.4.1.18070.2.2.1.4.16.1.24 |
| briCustom1 A variable length text string for operating company use. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.18070.2.2.1.4.16.1.25 |
| briBitRate The bit rate transmitted by the BRI facility port in Mbps. | column | BTI-TC-MIBFixedX100 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.26 |
| briRemoteId Identifies the remote node and port to which the
Bitrate Independent port is connected, in the
format prescribed by the PSM network management
system. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.18070.2.2.1.4.16.1.27 |
| briPortIdx The number of the port on the circuit pack on which the
BRI facility is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.3 |
| briProtocol The protocol of the BRI signal which is provisioned. | column | Enumeration | .1.3.6.1.4.1.18070.2.2.1.4.16.1.4 |
| briOpticalPwrReceivedMinTh This is the optical power received minimum threshold. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.5 |
| briOpticalPwrReceivedMaxTh This is the optical power received maximum threshold. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.6 |
| briOpticalPwrTransmittedMinTh This is the optical power transmitted minimum threshold. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.7 |
| briOpticalPwrTransmittedMaxTh This is the optical power transmitted maximum threshold. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.8 |
| briOpticalPwrReceived The optical power received on the input of the transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.4.16.1.9 |