briHistPMIntervalTypeIdx
BTI-7000-MIB ·
.1.3.6.1.4.1.18070.2.2.1.6.39.1.4
Object
column
BTI-TC-MIBPMIntervalType
The type of PM bin according to interval length.
Context
- MIB
- BTI-7000-MIB
- OID
.1.3.6.1.4.1.18070.2.2.1.6.39.1.4- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- briHistPMEntry
- Table
- briHistPMTable
- Siblings
- 43
Syntax
BTI-TC-MIBPMIntervalType
- Source
- BTI-TC-MIBPMIntervalType
- Base type
Enumeration
Values & Constraints
Type Values
1 | min15 |
2 | day1 |
3 | untimed |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| briHistPMShelfIdx The number of the shelf on which the BRI facility targeted for
PMs is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.1 |
| briHistPMOPTTimeStamp The date and time stamp of the optical power transmitted
value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.10 |
| briHistPMOPTValidity Indicates the validity of the provided optical power
transmitted value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.11 |
| briHistPMTempValue The temperature measured on the BRI facility port. | column | degrees Celsius Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.12 |
| briHistPMTempTimeStamp The date and time stamp of the temperature value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.13 |
| briHistPMTempValidity Indicates the validity of the provided temperature value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.14 |
| briHistPMSupplyVoltageValue The supply voltage measured on the BRI facility port. | column | mVolts/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.15 |
| briHistPMSupplyVoltageTimeStamp The date and time stamp of the supply voltage value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.16 |
| briHistPMSupplyVoltageValidity Indicates the validity of the provided supply voltage value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.17 |
| briHistPMLBCValue The laser bias current measured on the BRI facility port. | column | mAmp Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.18 |
| briHistPMLBCTimeStamp The date and time stamp of the laser bias current value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.19 |
| briHistPMSlotIdx The number of the slot within which the BRI facility targeted
for PMs is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.2 |
| briHistPMLBCValidity Indicates the validity of the provided laser bias current
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.20 |
| briHistPMOPRMinValue The minimum optical power received on the input of the transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.21 |
| briHistPMOPRMinTimeStamp The date and time stamp of the minimum optical power received value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.22 |
| briHistPMOPRMinValidity Indicates the validity of the provided minimum optical power received
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.23 |
| briHistPMOPRMinInitialize Used to initialize the value of the briHistPMOPRMinValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.39.1.24 |
| briHistPMOPRMaxValue The maximum optical power received on the input of the transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.25 |
| briHistPMOPRMaxTimeStamp The date and time stamp of the maximum optical power received value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.26 |
| briHistPMOPRMaxValidity Indicates the validity of the provided maximum optical power received
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.27 |
| briHistPMOPRMaxInitialize Used to initialize the value of the briHistPMOPRMaxValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.39.1.28 |
| briHistPMOPRAvgValue The average optical power received on the input of the transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.29 |
| briHistPMPortIdx The number of the port on the circuit pack on which the BRI
facility targeted for PMs is provisioned. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.3 |
| briHistPMOPRAvgTimeStamp The date and time stamp of the average optical power received value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.30 |
| briHistPMOPRAvgValidity Indicates the validity of the provided average optical power received
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.31 |
| briHistPMOPRAvgInitialize Used to initialize the value of the briHistPMOPRAvgValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.39.1.32 |
| briHistPMOPTMinValue The minimum optical power transmitted at the output of the
transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.33 |
| briHistPMOPTMinTimeStamp The date and time stamp of the minimum optical power transmitted
value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.34 |
| briHistPMOPTMinValidity Indicates the validity of the provided minimum optical power
transmitted value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.35 |
| briHistPMOPTMinInitialize Used to initialize the value of the briHistPMOPTMinValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.39.1.36 |
| briHistPMOPTMaxValue The maximum optical power transmitted at the output of the
transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.37 |
| briHistPMOPTMaxTimeStamp The date and time stamp of the maximum optical power transmitted
value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.38 |
| briHistPMOPTMaxValidity Indicates the validity of the provided maximum optical power
transmitted value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.39 |
| briHistPMOPTMaxInitialize Used to initialize the value of the briHistPMOPTMaxValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.39.1.40 |
| briHistPMOPTAvgValue The average optical power transmitted at the output of the
transceiver. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.41 |
| briHistPMOPTAvgTimeStamp The date and time stamp of the average optical power transmitted
value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.42 |
| briHistPMOPTAvgValidity Indicates the validity of the provided average optical power
transmitted value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.43 |
| briHistPMOPTAvgInitialize Used to initialize the value of the briHistPMOPTAvgValue
object to 0. | column | BTI-TC-MIBInitializeCmd | .1.3.6.1.4.1.18070.2.2.1.6.39.1.44 |
| briHistPMIntervalIdx The specific PM bin number. The range is 1 to 96 for the
15-minute historical bins. For the 1-day historical bin, the
value is 1. | column | Integer32 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.5 |
| briHistPMOPRValue The optical power received on the input of the BRI facility
port. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.6 |
| briHistPMOPRTimeStamp The date and time stamp of the optical power received value. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.18070.2.2.1.6.39.1.7 |
| briHistPMOPRValidity Indicates the validity of the provided optical power received
value. | column | BTI-TC-MIBPMValidity | .1.3.6.1.4.1.18070.2.2.1.6.39.1.8 |
| briHistPMOPTValue The optical power transmitted at the output of the BRI facility
port. | column | dBm/10 BTI-TC-MIBFixedX10 | .1.3.6.1.4.1.18070.2.2.1.6.39.1.9 |